It is possible to configure the
File Retrieval
to delete files once retrieved from
the datalogger. If datalogger memory capacity is a concern, it is recommended
to use this feature.
To add a file retrieval process, start by clicking
Add New
under
File Pattern
.
Once added, the
Edit File Pattern
,
Output Directory
, and
Max Files
parameter become available to fill out. Each
File Pattern
added will need to be
individually configured.
Under the
Edit File Pattern
parameter, select from the directory location
options, in order to specify the image or video to be retrieved. By default, the
jpg and avi names are a wild card (*), which means all jpg or avi files in the
specified directory will be retrieved. If specific filenames are used in the
camera configuration, specify these names in the
Edit File Pattern
parameter.
It is possible to configure multiple
File Patterns
to collect images or video on
different schedules or from multiple directories.
If the version of
LoggerNet
File Retrieval
does not list the avi files
as an option under
Edit File Pattern
, it is possible to force the
filename and format by typing the filename or suffix into the
Edit
File Pattern
parameter.
The default Output Directory is C:\Campbellsci\LoggerNet. If required, change
this by browsing to the preferred location. The
Max Files
parameter specifies
the maximum number of files that can be retrieved during each scheduled
event. The newest files will be retrieved.
When the
Force Retrieval
box is selected, a file that matches the file pattern
will be retrieved regardless of the file’s timestamp or whether the file has
already been retrieved. When the
Record If Skipped
box is selected, the
names and dates of any files that are not retrieved because of the
Max Files
parameter will be recorded and they will not be retrieved later. If this box is not
selected, the skipped files can be retrieved in a later attempt.
8.14.2 Using
LoggerNet
File Control
Images or video that are in the dataloggers memory can be viewed or collected
on demand by using the
File Control
feature that is available from the
Connection Screen
menu (FIGURE
). The use of
File Control
requires a
communications connection to the datalogger. Using the
File Control
can also
be useful for debugging purposes.