![Campbell 03002 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/campbell/03002/03002_product-manual_3752597016.webp)
Figure 7-2. CM221 Right-Angle Mounting Kit
Figure 7-3. The CM216 allows an 03002 or 03101 to mount atop a tripod mast
7.5 Mounting the 03101 anemometer to a
crossarm
1. Install the cup wheel to the anemometer shaft using the hex key wrench provided with the
sensor.
2. Mount a crossarm to a tripod or tower.
3. Secure the 3/4-inch IPS, 10-inch-long, threaded aluminum pipe to the CM220 mount or
3/4 x 1 inch Nu-Rail fitting (
4. Place the 03101 on the pipe.
5. Route the sensor cable along the underside of the crossarm to the tripod or tower, and to
the instrument enclosure.
6. Secure the cable to the crossarm and tripod or tower by using cable ties.
Wind Sentry Series