03002 R.M. Young Wind Sentry Set

03101 R.M. Young Wind Sentry Anemometer

03301 R.M. Young Wind Sentry Vane

Revision: 9/13

 

 

 

 

 

 

 

 

 

 

 

 

 

C o p y r i g h t   ©   1 9 8 6 - 2 0 1 3

C a m p b e l l   S c i e n t i f i c ,   I n c .

Содержание 03002 R.M

Страница 1: ...03002 R M Young Wind Sentry Set 03101 R M Young Wind Sentry Anemometer 03301 R M Young Wind Sentry Vane Revision 9 13 C o p y r i g h t 1 9 8 6 2 0 1 3 C a m p b e l l S c i e n t i f i c I n c ...

Страница 2: ......

Страница 3: ...removing reinstalling and shipping defective products to Campbell Campbell will return such products by surface carrier prepaid within the continental United States of America To all other locations Campbell will return such products best way CIP Port of Entry INCOTERM 2010 prepaid This warranty shall not apply to any products which have been subjected to modification misuse neglect improper servi...

Страница 4: ...ng container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Cleanliness and Decontamination form and comply with the requirements specified in it The form is available from our web site at www campbellsci com repair A completed form must be either emailed to repa...

Страница 5: ...talogger and Generate Wiring Diagram 5 5 Overview 7 6 Specifications 8 6 1 Wind Speed Anemometer 8 6 2 Wind Direction Vane 9 6 3 Wind Sentry Assembly 9 7 Installation 9 7 1 Siting 9 7 2 Assembly and Mounting 10 7 2 1 03002 Wind Sentry Set 10 7 2 2 03101 Anemometer 10 7 2 3 03301 Vane 11 7 3 Wiring 11 7 4 Programming 13 7 4 1 Wind Speed 13 7 4 2 Wind Direction 13 7 4 3 Wind Vector Processing Instru...

Страница 6: ...16 allows an 03002 or 03101 to mount atop the mast of a CM110 CM115 or CM120 tripod 10 7 2 03101 mounted to a crossarm via a 1049 NU RAIL 11 A 1 Magnetic declination for the contiguous United States 2004 A 2 A 2 Declination angles east of True North are subtracted from 0 to get True North A 3 A 3 Declination angles west of True North are added to 0 to get True North A 3 B 1 03002 and 03301 potenti...

Страница 7: ...ounting the 03002 or before raising a tower The black outer jacket of the cable is Santoprene rubber This compound was chosen for its resistance to temperature extremes moisture and UV degradation However this jacket will support combustion in air It is rated as slow burning when tested according to U L 94 H B and will pass FMVSS302 Local fire codes may preclude its use inside buildings 3 Initial ...

Страница 8: ... 4 1 Step 1 Mount the Sensor This quick start is for the 03002 wind set Refer to Section 7 Installation if installing just the 03101 anemometer or 03301 vane Section 7 Installation also provides siting information Tools required 5 64 Allen wrench Allen wrench provided with sensor 1 2 open end wrench compass and declination angle for the site see Appendix A small screw driver provided with datalogg...

Страница 9: ... CM220 mount or 17953 NU RAIL The 3659 aluminum pipe is shipped with the 03002 5 Place the 03002 on the pipe and orient the sensor crossarm North South with the vane to the North 6 Tighten the mounting post band clamp Final sensor orientation is done after the datalogger has been programmed to measure wind direction as described in Appendix A 7 Route the sensor cable along the underside of the cro...

Страница 10: ...RE 4 2 03002 mounted to CM200 Series Crossarm with CM220 FIGURE 4 3 03002 mounted to CM200 Series Crossarm with pn 17953 CM220 Alumimum Pipe CM200 Series Crossarm pn 17953 NU RAIL Aluminum Pipe CM200 Series Crossarm Cable Tie 4 ...

Страница 11: ...and Generate Wiring Diagram The simplest method for programming the datalogger to measure the 03002 is to use Campbell Scientific s SCWin Short Cut Program Generator 1 Open Short Cut and click on New Program 2 Select the Datalogger and enter the Scan Interval and select Next 5 ...

Страница 12: ...try 3 Select 03002 Wind Speed Direction Sensor and select the right arrow in center of screen to add it to the list of sensors to be measured then select Next 4 Select Wind Vector for the output and then select Finish 6 ...

Страница 13: ...by a 10 kΩ potentiometer With a precision excitation voltage applied the output voltage is proportional to wind direction The 03101 Anemometer and 03301 Vane can be ordered as separate sensors which are also covered in this manual These two sensors combined differ from the 03002 only by the absence of a junction box The R M Young Instruction Manual includes additional information on the operating ...

Страница 14: ... in adverse conditions Small size simplicity and rugged construction provide a quality instrument for a modest price Ideal for wind profile studies Compatible with the LLAC4 4 channel Low Level AC Conversion Module which increases the number of anemometers one datalogger can measure Campbell Scientific version uses shielded bearings which lowers the anemometer s starting threshold Compatible Datal...

Страница 15: ...tion Requirement Regulated dc voltage 15 Vdc max Output Analog dc voltage proportional to wind direction angle with regulated excitation voltage supplied by the datalogger Vane Length 22 cm 8 7 in Vane Weight 170 g 6 oz 6 3 Wind Sentry Assembly Operating Temperature 50 to 50 C assuming non riming conditions Overall Height 32 cm 12 6 in Crossarm Length 40 cm 15 7 in between instruments center to ce...

Страница 16: ...rt describes mounting the 03002 using a CM220 mount or a 17953 NU RAIL fitting The 03002 can also be mounted at the top of a CM110 CM115 or CM120 tripod with the CM216 see FIGURE 7 1 The 03002 mounts to a standard 1 0 in IPS schedule 40 pipe 1 34 in O D A 12 long mounting pipe ships with the 03002 The mounting pipe typically fastens to a CM200 series crossarm via the CM220 mount or 17953 NU RAIL f...

Страница 17: ...ssarm via a 1049 NU RAIL Cable Tie Crossarm 1049 NU RAIL Fitting 7 2 3 03301 Vane The 03301 vane is typically ordered as a replacement vane for the 03002 Wind Sentry Set and includes the bracket for attaching it to the 03002 small crossarm Part number 4913 pipe mount not included with the sensor can be used to attach the 03301 to a CM200 series crossarm with the CM220 or pn 1049 and the mounting p...

Страница 18: ...g Blue Wind Dir Excitation Excitation Excitation Excitation Excitation TABLE 7 2 03101 and 03301 Wiring Color Description CR800 CR5000 CR3000 CR1000 CR510 CR10 X CR21X CR7 CR23X CR200 X Black Wind Spd Signal Pulse Pulse Pulse P_LL White Wind Spd Reference G Clear Wind Spd Shield G Red Wind Dir Signal SE Analog SE Analog SE Analog SE Analog Black Wind Dir Excitation Excitation Excitation Excitation...

Страница 19: ...ion is configured to output the result in hertz TABLE 7 3 Wind Speed Multiplier With Pulse Channel Configuration Set to Low Level AC Output Hz Model Meters Second Miles Hour 03002 03101 M 0 750 Off 0 2 M 1 677 Off 0 4 When the pulse channel configuration is set to Low Level AC output counts the multiplier above is divided by the execution interval in seconds 7 4 2 Wind Direction The wind vane is c...

Страница 20: ...wind speed unit vector mean wind direction and standard deviation of the wind direction optional from the measured wind speed and direction values 7 4 4 Example Programs The following programs measure the 03002 every 5 seconds and store mean wind speed unit vector mean direction and standard deviation of the direction every 60 minutes Wiring for the examples is given in TABLE 7 5 TABLE 7 5 Wiring ...

Страница 21: ... Wind Speed Sensor measurement WS_ms PulseCount WS_ms 1 1 1 1 0 75 0 2 If WS_ms 0 21 Then WS_ms 0 03002 or 03301 RM Young Wind Sentry Wind Direction Sensor measurement WindDir BrHalf WindDir 1 mV2500 1 1 1 2500 True 0 _60Hz 352 0 Use mV5000 range and 5000 mV excitation for CR3000 and CR5000 dataloggers If WindDir 360 OR WindDir 0 Then WindDir 0 Call Data Tables and Store Data CallTable Table1 Next...

Страница 22: ...Channel 4 1 Excite all reps w Exchan 1 5 2 Delay 0 01 sec units 6 2500 mV Excitation 5000 mV for CR23X 21X or CR7 7 3 Loc WindDir 8 0 1408 Multiplier 0 0704 for CR23X 21X or CR7 9 0 Offset 7 If X F P89 1 3 X Loc WindDir 2 3 3 360 F 4 30 Then Do 8 Z F x 10 n P30 1 0 F 2 0 n Exponent of 10 3 3 Z Loc WindDir 9 End P95 10 If X F P89 1 3 X Loc WindDir 2 4 3 0 F 4 3 Then Do 11 Z F x 10 n P30 1 0 F 2 0 n...

Страница 23: ...roseconds The 60 Hz rejection option can not be used with the DC Half Bridge instruction when the delay is not zero Do not use long lead lengths in electrically noisy environments CAUTION 8 Sensor Maintenance Every month do a visual audio inspection of the anemometer at low wind speeds Verify that the cup assembly and wind vane rotate freely Inspect the sensor for physical damage Replace the anemo...

Страница 24: ... range code multiplier and offset parameters are correct for the datalogger type 2 Check orientation of sensor as described in Section 4 1 Step 1 Mount the Sensor 9 2 Wind Speed Symptom No wind speed 1 Check that the sensor is wired to the pulse channel specified by the pulse count instruction 2 Disconnect the sensor from the datalogger and use an ohm meter to check the coil The resistance between...

Страница 25: ... Site Meteorological Program Guidance for Regulatory Modeling Applications EPA 450 4 87 013 Office of Air Quality Planning and Standards Research Triangle Park NC 27711 The State Climatologist 1985 Publication of the American Association of State Climatologists Height and Exposure Standards for Sensors on Automated Weather Stations vol 9 No 4 WMO 1983 Guide to Meteorological Instruments and Method...

Страница 26: ...R M Young Wind Sentry 20 ...

Страница 27: ...ative and are subtracted from 360 degrees to get True North as shown FIGURE A 2 0 and 360 are the same point on a compass Declination angles west of True North are considered positive and are added to 0 degrees to get True North as shown in FIGURE A 3 For example the declination for Logan Utah is 14 East True North is 360 14 or 346 as read on a compass Orientation is most easily done with two peop...

Страница 28: ...Appendix A Wind Direction Sensor Orientation FIGURE A 1 Magnetic declination for the contiguous United States 2004 A 2 ...

Страница 29: ...A Wind Direction Sensor Orientation FIGURE A 2 Declination angles east of True North are subtracted from 0 to get True North FIGURE A 3 Declination angles west of True North are added to 0 to get True North A 3 ...

Страница 30: ...Appendix A Wind Direction Sensor Orientation A 4 ...

Страница 31: ...lue that Rs will reach is Rf just before it crosses over from the west side of north to the east side of north at this point Rt 0 Vs Vx reaches its maximum value of 1 0 mV mV at 352 degrees The multiplier to convert Vs Vx to degrees is 352 degrees 1 0 Vs Vx 352 Since the datalogger outputs the ratio Vs Vx the multiplier is the same for both the CR10 X and CR3000 even though they use a different ex...

Страница 32: ...alue of Vx This maximum voltage equals 2500 mV for an excitation voltage of 2500 mV recommended for the CR10 X and 5000 mV for an excitation voltage of 5000 mV recommended for the CR23X at 352 degrees The multiplier to convert Vs to degrees is 352 degrees 2500 mV 0 1408 for the CR10X or 352 degrees 5000 mV 0 0704 for the CR23X See Section 13 5 in the datalogger manual from more information on the ...

Страница 33: ...GICAL INSTRUMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com P N 03002 5 90 REV D110210 WIND SENTRY MODEL 03002 5 ...

Страница 34: ...eadings signal conditioning electronics should clamp the signal to excitation or reference level when this occurs Note All YOUNG signal conditioning devices clamp the signal to excitation level Avoid a short circuit between the wind direction signal line and either the excitation or ground reference lines Although there is a current limiting resistor in series with the wiper for protection damage ...

Страница 35: ...ection signal should correspond to 180 or due south Looking from above visually align the vane with each of the crossmarkings and observe the indicator display It should correspond to vane position within 5 If not it may be necessary to adjust the relative position of the vane skirt and shaft See step 3 in the MAINTENANCE section under potentiometer replacement It is important to note that while t...

Страница 36: ... bearing on shaft inside upper housing d Using ring magnet assembly push lower bearing into its seat in upper housing e Secure ring magnet to shaft using screw removed in step 1d Use a small amount of sealant on screw to prevent it from loosening f Join two housing sections Secure using three screws removed in step 1b g Place cup wheel on shaft Tighten set screw on side of hub Do not exceed 80 oz ...

Страница 37: ...Page 4 03002 5 90 D CABLE WIRING DIAGRAM ...

Страница 38: ...Page 5 03002 5 90 D GENERAL ASSEMBLY REPLACEMENT PARTS ...

Страница 39: ......

Страница 40: ...1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www campbellsci cc info campbellsci cc Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd CSL France 3 A...