Camozzi D Series Скачать руководство пользователя страница 1

SERIES D

SERIES CX4

ETHERNETIP V 1.0

USE AND MAINTENANCE MANUAL

Содержание D Series

Страница 1: ...SERIES D SERIES CX4 ETHERNETIP V 1 0 USE AND MAINTENANCE MANUAL...

Страница 2: ...sories 12 5 5 Assembly 13 5 5 1 Dismantling and fitting CX4 module 13 5 5 2 Series D subbases assembly 14 5 5 3 Dismantling and fitting Serie D coil valves 15 5 5 4 I O modules assembly 16 5 5 5 Disma...

Страница 3: ...gnostics 59 7 Commissioning 61 7 1 Electrical connections 61 7 2 Start up operation 61 7 3 Mapping 62 7 4 Addressing EtherNet IP network 62 7 5 Configuration via EDS file 62 7 6 Address assignment 63...

Страница 4: ...gital Input Module 109 8 4 Digital Output Module 110 8 5 Analogue Input Module 111 8 6 Analogue Output Module 112 9 Uvix 113 9 1 Introduction 113 9 2 General information 114 9 2 1 Status information 1...

Страница 5: ...figuration 139 9 7 3 Variables 140 9 7 4 Alarms 140 9 7 5 Commands 141 9 8 UVIX USB Gateway 142 9 8 1 Main page 142 9 8 2 WiFi network configurator 143 9 8 3 Mapping 143 9 8 4 Firmware update 143 9 9...

Страница 6: ...ecommended to minimise the risk of phys ical injury For all situations not contemplated in this manual and in situations in which there is the risk of potential damage to property or injury to persons...

Страница 7: ...ception of specific intended uses do not use the product in environments where direct contact with corrosive gases chemicals salt water water or steam may occur 1 4 Maintenance Incorrectly performed m...

Страница 8: ...of the product s life cycle it is recommended to separate the materials for recycling Follow the waste disposal regulations in force in your country The product and relative parts all comply with the...

Страница 9: ...pe M12 5 poles Supply voltage Logic 24 V DC 25 Supply voltage Power 24 V DC 10 Valve maximum absorption 2 5 A Maximum no valve positions 64 128 coils Coil power 1W reduction to 0 5W after 100ms Maximu...

Страница 10: ...he pitch Temperature 0 50 C Air feature Compressed air filtered and not lubricated in class 7 4 4 according to ISO 8573 1 2010 If lubrication is required use only oils with max viscosity 32Cstandtheve...

Страница 11: ...icated to Industry 4 0 because it is a SMART device capable of connecting to other devices or networks ex WiFi USB NFC for information exchange The system can transmit data of the main variables the...

Страница 12: ...or qualified experts in control and automation technologies who have experience in the installation commissioning programming and diagnostics of programmable logic controllers PLCs and fieldbus system...

Страница 13: ...LEDs SYS island status LED Link L A1 LED Link L A2 LED EtherNet IP MS LED EtherNet IP NS LED Connector to the EtherNet IP network OUT M12D 4 pole female connector Connector to the EtherNet IP network...

Страница 14: ...P network IN and OUT are M12D 4 pole female PIN Signal Description Symbol 1 TD Transmission data 2 RD Reception data 3 TD Transmission data 4 RD Reception data NOTE To avoid malfunctions due to faulty...

Страница 15: ...cro version The connector allows the CX4 to be con nected to the UVIX interface for monitoring or configuration NOTE The dedicated USB connector can be found in the Camozzi catalogue G11W G12W 2 stand...

Страница 16: ...bsequently the coil valves are kept activated by reducing the absorbed power to 50 of the initial value by means of a PWM control technique The permitted power supply voltage for the series D valve is...

Страница 17: ...ences to the technical details in the manual Series D subbase and coil valves in three different sizes par 6 1 8 or 16 channel digital input module par 6 2 8 or 16 channel digital output module par 6...

Страница 18: ...ting from the manifold base Fit the CX4 module as follows 1 Switch off the operating voltage supply of the CX4 module to avoid problems for the device or user 2 Make sure that the gaskets are tight an...

Страница 19: ...subbases pack 3 Remove the valves subbases from the tie rods and replace with the new modules 4 Push the valves subbases as far as possible to allow a correct electrical contact 5 Mount the cover at...

Страница 20: ...il valves 2 Pull the valves carefully and without tilting from the subbase to avoid damages 3 Add the new valves carefully and without tilting to the subbase to avoid damages 4 Tighten the 2 screws To...

Страница 21: ...pen the I O pack 3 Remove the I O modules from the tie rods and replace with the new modules 4 Push the I O modules as far as possible to allow a correct electrical contact 5 Mount the cover at the en...

Страница 22: ...rom the manifold base Fit the cover of the I O module as follows 1 Switch off the operating voltage supply of the CX4 module to avoid problems for the device or user 2 Make sure that the gaskets are t...

Страница 23: ...he subbases on the pneumatic side to allow the new Camozzi Series D coil valves to be connected Series D valves are available in three sizes depending on the pitch Series D1 coil valves 10 5 mm pitch...

Страница 24: ...Coilvision The subbases of Series D valves are equipped with COILVISION technology This technology was devel oped to constantly monitor the functional parameters of the coil that drives the spool Each...

Страница 25: ...e state you want to set the valve coils to Fail Safe Status By default the coil is off Coil management error locking can also be enabled Error Enable By default it is disabled If enabled errorsdonotsi...

Страница 26: ...sive and therefore the coil valve is automatically switched off Solution replace the coil valve Overheating coil 3 flashes YELLOW 100 ms every 1 s The coil temperature is too high This alarm may be bl...

Страница 27: ...ltage in the second case the reverse will apply Regardingthetemporalcharacteristicsoftheinputsignals configurationdoesnottakeplaceonachannel by channel basis the values associated with the parameters...

Страница 28: ...D Input 8 connector Input 1 connector Input 2 status yellow LED Input 3 connector Input 4 status yellow LED Input 5 connector Input 6 status yellow LED Input 7 connector Input 8 status yellow LED M8 c...

Страница 29: ...nputs 5 and 6 connector Input 6 status yellow LED Inputs 7 and 8 connector Input 8 status yellow LED M12 connectors pinout PIN Signal Description Symbol 1 VCC 24 Vdc power supply for outside 2 Input n...

Страница 30: ...Input 2 status yellow LED Input 3 status yellow LED Input 4 status yellow LED Connettore ingressi 9 16 Input 9 status yellow LED Input 10 status yellow LED Input 11 status yellow LED Input 12 status y...

Страница 31: ...escription Symbol 1 Input power supply 24Vdc 2 GND reference Connection mode The cables must have a cross section of 0 5mmq and a 0 4x2 screwdriver can be used to remove the terminal block from the mo...

Страница 32: ...e mapping phase and is turned off if this procedure is completed success fully Waiting for configuration parameters 1 flash RED 100 ms every 2 s The module is waiting for configuration parame ters max...

Страница 33: ...e remaining channels from 2 to 16 i e it is lit and yellow when the input is active and off when the input is inactive Input status LED status Description Input n inactive YELLOW OFF The LED indicates...

Страница 34: ...r is present and the digital inputs are externally powered For this mode the pa rameter for using the external power supply must be configured correctly No external power supply RED ON The module is c...

Страница 35: ...at least one output is activated without the presence of a load the module detects the fault which is then signalled by a specific alarm Channel enabling Enable output channels the single bits that m...

Страница 36: ...onds from 0 to 255 In particular when a PWM channel is activated it imme diately assumes a duty cycle equal to 100 and maintains it until the specified time has elapsed from that moment on the PWM sig...

Страница 37: ...w LED Output 8 connector Output 1 connector Output 2 status yellow LED Output 3 connector Output 4 status yellow LED Output 5 connector Output 6 status yellow LED Output 7 connector Output 8 status ye...

Страница 38: ...Outputs connector 5 and 6 Output 6 status yellow LED Outputs connector 7 and 8 Output 8 status yellow LED M12 connectors pinout PIN Signal Description Symbol 1 VCC 24 Vdc power supply for outside 2 Ou...

Страница 39: ...us yellow LED Output 4 status yellow LED Connettore uscite 9 16 Output 9 status yellow LED Output 10 status yellow LED Output 11 status yellow LED Output 12 status yellow LED External Power Connector...

Страница 40: ...age 12 32 Vdc 2 GND reference NOTE The 16 channel digital output module must be externally powered Connection mode The cables must have a cross section of 0 5mmq and a 0 4x2 screwdriver can be used to...

Страница 41: ...configuration parameters are received Mapped module RED ON The LED is lit during the mapping phase and is switched off if this procedure is completed suc cessfully Waiting for configuration parameter...

Страница 42: ...he correct operating range Vcc 24 V No voltage supply For 16 channel modules only 4 flashes RED 100 ms every 2 s Circuit power is missing or shorted Solution check that the power reaches the module co...

Страница 43: ...cessfully Diagnostic LED of the external power supply In the 16 channel configuration the digital output module is equipped with a connector for the exter nal power supply with associated signalling L...

Страница 44: ...achchannelrestorestheconversionofthecorrespondinginputintoa16 bitor32 bitword Thedatum is represented in 2 s complement and depending on the module corresponds to different values Module Word transmit...

Страница 45: ...he head in two different ways in frequency and threshold When the transmission is configured in frequency Sampling Threshold and Sampling Threshold Timeout parametersdisabled itispossibletosetatransmi...

Страница 46: ...data acquired by the inputs and the related diagnostics to the PLC in the following cases If the temperature measurement at the current time of either input exceeds the previous one by at least 0 2 C...

Страница 47: ...analogue module with 5 pole female TB connectors Module diagnostics red LED Channel 1 yellow LED Channel 2 yellow LED Channel 1 connector Channel 2 connector Module diagnostics red LED Channel 1 yello...

Страница 48: ...F The module is waiting for configuration parameters maximum duration 1 minute Sensor working on channel 1 RED OFF YELLOW ON YELLOW OFF The sensor connected to channel 1 is functioning correctly Senso...

Страница 49: ...s and restart the module Sensor alarm on channel 2 2 flashes RED 100 ms every 2 s YELLOW OFF 2 flashes YELLOW 100 ms every 2 s Sensor fault enabled and connected on channel 2 Solution check that the s...

Страница 50: ...W OFF It occurs in the event of communication problems between the microcontroller and the ADC that measures the physical input quantity Solution contact support and replace the module Reference volta...

Страница 51: ...5 200 850 PT500 385 200 850 PT1000 385 200 850 Ni100 618 60 180 Ni120 672 80 260 Ni1000 618 60 250 Type of connections 2 3 4 wires Number of inputs 2 Sensor connections M12 A coded 5 pole female conne...

Страница 52: ...re RTDs must be connected between pin 2 and pin 3 of the connector compensation wires to pin 1 and 4 Possible types of connections 2 3 4 fili M12A connector TB connector Faults The module is able to d...

Страница 53: ...00 R 50 1768 1 S 50 1768 1 T 200 400 Number of inputs 2 Sensor connections M12 A coded 5 pole female connectors for each input TB 5 pole female connectors for each input Converter resolution 16 bit Re...

Страница 54: ...n M12A connector TB connector 1 CJC PT100 for cold junction compensation do not connect 2 TC Thermocouple positive input 3 CJC PT100 for cold junction compensation do not connect 4 TC Thermocouple neg...

Страница 55: ...mV V Number of inputs 2 Sensor connections M12 A coded 5 pole female connectors for each input TB 5 pole female connectors for each input Converter resolution 24 bits Reading resolution 1 uV Measureme...

Страница 56: ...stor bridge The voltage to weight conversion formula for load cells is as follows F FN U C UEXC Dove F is the force detected by the load cell Kg FN is the capacity of the load cell Kg C is the sensiti...

Страница 57: ...78 1 0 0243 16 156 3 0 0128 32 312 5 0 0067 64 625 0 0 0062 128 1250 0 0 0056 256 2500 0 0 0064 Faults The module is able to detect the following faults Short circuit between ECC and ECC pin excitati...

Страница 58: ...ections M12 A coded 5 pole female connectors for each input TB 5 pole female connectors for each input Converter resolution 16 bit Reading resolution 1 mV 160 2 V RAW 1 A 259 4 nA RAW Measurement erro...

Страница 59: ...0 mA per channel or 400 mA if there is only one sensor powered by the board Data range Error range Error range 10 V 4 20 mA 4 20 mA RAW 20 mA 10500 mV 3500 A 0 3 5 mA 20500 A 10000 mV 4000 A 2979 4 mA...

Страница 60: ...ed in a 16 bit number and it is considered the technical range 0 10 V RAW V V 10 5V 65535 RAWV AL 4 20 mA RAW I mA 17mA 65535 RAWV AL 3 5mA Faults The module is able to detect the following faults Min...

Страница 61: ...meters have been received the mod ule enters normal operating status and the outputs if enabled can be set Otherwise if the mapping procedure does not finish correctly the module remains in an error s...

Страница 62: ...to assign default values both in voltage and in current to the analogue outputs failsafe In particular for each channel you can assign the value it had before the communication failure failsafe disab...

Страница 63: ...s have specific pinouts dedicated to their functionality Visual indication of operation and diagnostics is via three LEDs Module diagnostics red LED Channel 1 yellow LED Channel 2 yellow LED Channel 1...

Страница 64: ...YELLOW OFF The output to channel 1 is functioning correctly Output working Channel 2 RED OFF YELLOW OFF YELLOW ON The output to channel 2 is functioning correctly Communication fault 2 flashes RED 100...

Страница 65: ...t 2 not present This error is valid only for the current configuration Solution check connections with the load and restart the module Module error 4 flashes RED 100 ms every 2 s 4 flashes YELLOW 100...

Страница 66: ...f the system has been modified a new mapping re quest must be made par 7 3 During the mapping operation the general diagnostic LEDs of each connected accessory device light up in sequence first on the...

Страница 67: ...EtherNet IP network The default settings for our system are as follows Station name not used IP address 192 168 10 2 Network mask 255 255 255 0 Gateway 0 0 0 0 There are several ways to edit the defa...

Страница 68: ...l digital input modules 8 1 byte 8 8 bytes 64 digital inputs 16 channel digital input modules 16 2 bytes 6 12 bytes 96 digital inputs 8 channel digital output modules 8 1 byte 8 8 bytes 64 digital out...

Страница 69: ...dules 16 2 bytes 6 12 bytes 96 digital inputs 8 channel digital output modules 8 1 byte 8 8 bytes 64 digital outputs 16 channel digital output modules 16 2 bytes 6 12 bytes 96 digital outputs Analogue...

Страница 70: ...bases 2 2 bits for valve 64 16 bytes 128 coils 8 channel digital input modules 8 1 byte 8 8 bytes 64 digital inputs 16 channel digital input modules 16 2 bytes 4 8 bytes 64 digital inputs 8 channel di...

Страница 71: ...the CX4 system it s used for operating variables par 7 10 1 sending specific commands par 7 10 2 or parameterizing modules par 7 10 3 We have recently introduced in the CX4 system the possibility of...

Страница 72: ...ble reading by explicit message if it is the first time Communications UCMM Service 16 0x10 Class 0x64 Instance 1 Attribute 8 Press the Send Request button check the outcome OK in the Status top box 2...

Страница 73: ...ing the right offset of the module in the output stream par 7 9 2 2 Enable writing by explicit messages if it is the first time Communications UCMM Service 16 0x10 Class 0x64 Instance 1 Attribute 8 Pr...

Страница 74: ...ng other things the offset as sociated with each slave group This parameter identifies the initial position of the specific group of devices within the relative data stream The assemblies for cyclic d...

Страница 75: ...Output 24 8 bytes 4 64 Output Analog Output Voltage Current 36 24 bytes 6 12 Output Diagnostic 0 1 byte 1 Input 8 Channels Digital Input 1 8 bytes 8 64 Input 16 Channels Digital Input 9 8 bytes 4 64 I...

Страница 76: ...64 128 Output 8 Channels Digital Output 16 8 bytes 8 64 Output 16 Channels Digital Output 24 8 bytes 4 64 Output Analog Output Voltage Current 36 24 bytes 6 12 Output Diagnostic 0 1 bytes 1 Input 8 Ch...

Страница 77: ...cts specifying the Service Class Instance and Attribute Description Service Class Instance Attribute Dimension Value Valve health status 0x0E 0x64 1 1 1 byte for coil 0 100 Valve cycle counter 0x0E 0x...

Страница 78: ...application via Unconnected Explicit Messag ing UCMM packets Description Service Class Instance Attribute Dimension Value Mapping request 0x10 0x64 1 6 0 byte Reset sub base information 0x10 0x64 1 5...

Страница 79: ...CX4 EtherNet IP The System Start allows the CX4 head to work in two alternative modes if left at the default value 0 all the application parameters described in the following paragraphs although stil...

Страница 80: ...1 bit per coil LSB Coil 1 Disabled 0 failsafe not enabled Enabled 1 failsafe enabled 35 FSE Coils 121 128 0 0xFF LSB Coil 121 Failsafe status Valves Failsafe Status 40 FSE Coils 1 8 0 0xFF Bit mask 1...

Страница 81: ...a channel DI8 Activation Mode 80 DI8 AM Chs 1 8 Module 1 0 0xFF Bit mask 1 bit per channel LSB Coil 1 High 1 high active input Low 0 low active input 87 DI8 AM Chs 57 64 Module 8 0 0xFF LSB Channel 5...

Страница 82: ...low active input 211 DI16 AM Chs 89 96 Module 8 0 0xFF LSB Channel 89 Minimum dwell time of the input level anti bounce filter DI16 Min Activation Time 220 DI16 AT Module 1 0 255 Module 1 0 filter dis...

Страница 83: ...DI16 Power Source 240 DI16 Power S Module 1 0 1 Module 1 Internal 0 power connected to internal source External 1 power connected to external source 245 DI16 Power S Module 6 0 1 Module 6 Parameter co...

Страница 84: ...Parameter ID Name Value Dimension and note Module settings DO8 Modules Settings 120 DO8 MS Module 1 0 1 Module 1 Bit 0 Open Load Detection 1 Enabled 0 Disabled 127 DO8 MS Module 8 0 1 Module 8 Enable...

Страница 85: ...Channel 1 Mode N 0 type N channel Mode P 1 type P channel 147 DO8 CM Chs 57 64 Module 8 0 0xFF Module 8 LSB Channel 57 Fail safe enable DO8 Failsafe Enable 150 DO8 FSE Chs 1 8 Module 1 0 0xFF Module...

Страница 86: ...Channel 57 Channel Type Setting PWM DO8 Channel Type 170 DO8 CHT Chs 1 8 Module 1 0 0xFF Module 1 channels 1 8 1 bit per channel LSB Channel 1 ON OFF 0 channel on off no Pwm PWM 1 Pwm type channel 17...

Страница 87: ...s 270 DO16 EC Chs 1 8 Module 1 0 0xFF Module 1 channels 1 8 1 bit per channel LSB Channel 1 Disabled 0 channel disabled Enabled 1 channel enabled 281 DO16 EC Chs 89 96 Module 6 0 0xFF Module 6 LSB Cha...

Страница 88: ...failsafe enabled on channel 321 DO16 FSE Chs 89 93 Module 6 0 0xFF Module 6 LSB Channel 89 Fail safe status DO16 Failsafe Status 330 DO16 FSS Chs 1 8 Module 1 0 0xFF Module 1 channels 1 8 1 bit per c...

Страница 89: ...nel on off no Pwm PWM 1 Pwm type channel 361 DO16 CHT Chs 89 96 Module 6 0 0xFF Module 6 LSB Channel 89 PWM activation time DO16 PWM Activation Time 370 DO16 ACT all modules 0 255 For all channels and...

Страница 90: ...120 672 0111 Ni1000 618 1000 PT100 3926 RTD sensor type Module 1 Channel 2 AI RTD Sensor Type Ch 2 Module 1 402 RTD sensor type Module 2 Channel 1 AI RTD Sensor Type Ch 3 Module 2 404 RTD sensor type...

Страница 91: ...10 U 0111 20 U 1000 30 U 1001 40 U 1010 80 U 1011 100 U 1100 160 U 1101 500 U 1110 1000 U 1111 2000 Board transmission threshold in relative units 1 U 0 1 C Module 2 AI RTD Sampling Thr Module 2 410...

Страница 92: ...ission frequency to the master timed mode or upper frequency limit threshold mode Modulo 2 AI RTD Sampling Freq Module 2 413 Moving Average Filter Length Module 1 Channel 1 AI RTD FIR Ch 1 Ch 1 Module...

Страница 93: ...1 AI TH Sensor Type Ch 3 Module 2 422 Tipo sensore TC Module 2 Channel 2 AI TH Sensor Type Ch 4 Module 2 423 Board transmission threshold in relative units 1 U 0 1 C Module 1 AI TH Sampling Thr Module...

Страница 94: ...27 Transmission frequency to the master timed mode or upper frequency limit threshold mode Module 1 AI TH Sampling Freq Module 1 428 1 10 0000 disable 0001 1 Hz 0010 2 Hz 0011 5 Hz 0100 10 Hz 0101 25...

Страница 95: ...odule 1 430 0 128 0 1 disable 2 128 no of filter caps Moving Average Filter Length Module 1 Channel 2 AI TH FIR Ch 2 Module 1 431 Moving Average Filter Length Module 2 Channel 1 AI TH FIR Ch 3 Module...

Страница 96: ...3 Module 2 462 BRIDGE sensor type Module 2 Channel 2 AI BRG Sensor Type Ch 4 Module 2 463 Board transmission threshold in relative units 1 U 0 1 C Module 1 AI BRG Sampling Thr Module 1 464 0 15 0000...

Страница 97: ...67 Transmission frequency to the master timed mode or upper frequency limit threshold mode Module 1 AI BRG Sampling Freq Module 1 468 0 10 0000 disable 0001 1 Hz 0010 2 Hz 0011 5 Hz 0100 10 Hz 0101 25...

Страница 98: ...le 1 470 0 128 0 1 disable 2 128 n di tappi del filtro Moving Average Filter Length Module 1 Channel 2 AI BRG FIR Ch 2 Module 1 471 Moving Average Filter Length Module 2 Channel 1 AI BRG FIR Ch 3 Modu...

Страница 99: ...1 AI V C Sensor Type Ch 3 Module 2 442 V C sensor type Module 2 Channel 2 AI V C Sensor Type Ch 4 Module 2 443 Board transmission threshold in relative units 1 U 0 1 C Module 1 AI V C Sampling Thr Mo...

Страница 100: ...47 Transmission frequency to the master timed mode or upper frequency limit threshold mode Module 1 AI V C Sampling Freq Module 1 448 0 10 0000 disable 0001 1 Hz 0010 2 Hz 0011 5 Hz 0100 10 Hz 0101 25...

Страница 101: ...le 1 450 0 128 0 1 disabilitato 2 128 no of filter caps Moving Average Filter Length Module 1 Channel 2 AI V C FIR Ch 2 Module 1 451 Moving Average Filter Length Module 2 Channel 1 AI V C FIR Ch 3 Mod...

Страница 102: ...type V C Module 3 Channel 5 AO V C Sensor Type Ch 5 Module 3 504 1 byte Output type V C Module 3 Channel 6 AO V C Sensor Type Ch 6 Module 3 505 1 byte 0 disabled 1 0 10 V 2 0 5 V 3 4 20 mA 4 0 20 mA...

Страница 103: ...Failsafe Enable Ch 3 4 Module 2 521 1 byte Enable failsafe Module 3 Channel 5 6 AO V C v Ch 5 6 Module 3 522 1 byte Enable failsafe Module 4 Channel 7 8 AO V C Failsafe Enable Ch 7 8 Module 4 523 1 by...

Страница 104: ...O V C Failsafe Value Ch 6 Module 3 535 2 byte In mV uA 0 10000 if channel 0 10 V 0 5000 if channel 0 5 V 4000 20000 if channel 4 20 mA 0 20000 if channel 0 20 mA Failsafe value Module 4 Channel 7 AO V...

Страница 105: ...r each module the table refers to a red LED Symbol LED state Description RED OFF Led is OFF RED ON Led is ON FLASHING The led flashes with a specified sequence for each diagnostic state XX ms Hz per Y...

Страница 106: ...Chapter 8 Diagnostic I messaggi software che vengono instradati sulla rete EtherNet IP The UVIX user interface ch 9 5000041281 Ver 1 0 Camozzi Automation S p A 101...

Страница 107: ...g green MS Module Status RED ON Major fault If the device has detected a non recoverable major fault the module status indicator shall be steady red Flashing RED Minor fault If the device has detected...

Страница 108: ...t If one or more of the connections in which this device is the target has timed out the network status indicator shall be flashing red This shall be left only if all timed out connections are re esta...

Страница 109: ...e Module status and alarms LED SYS Diagnostic Status Byte 0 stream IN UVIX Normal operation 1 flash GREEN 100 ms every 1 s 0x00 I O modules absent 1 flash GREEN 100 ms every 1 s 0x01 I O modules absen...

Страница 110: ...100 ms every 1 s 0xFD Mapping I O modules error Alarm of mapping valves error 2 flashes RED 100 ms every 1 s 0xFE Mapping valves error Alarm of mapping absent 1 flash RED 100 ms every 1 s 0xFF Mappin...

Страница 111: ...act Camozzi support 8 1 6 Undervoltage alarm The CX4 module is powered with a voltage lower than the minimum acceptable value therefore cor rect operation of the system is not guaranteed Solution chec...

Страница 112: ...ssarytheaccessorymodulewherethe mapping ends first accessory module with diagnostic LED off If the problem persists contact Camozzi support 8 1 10 Solenoid valve or I O module alarms These alarms are...

Страница 113: ...gnostics and possible solutions to any alarms refer to the Accessories chapter par 6 1 4 Module status and alarms Diagnostic Status Byte 0 stream IN UVIX Configuration parameters 0xE6 Overheating subb...

Страница 114: ...on the module Details on LED diagnostics and possible solutions to any alarms can be found in the chapter Accessories par 6 2 5 Module status and alarms Diagnostic Status Byte 0 stream IN UVIX Short c...

Страница 115: ...The 16 channel digital output modules mandatorily need external power supply Module status and alarms Diagnostic Status Byte 0 stream IN UVIX Short circuit on the channel n 0xCA Short Circuit Channel...

Страница 116: ...he chapter Accessories par 6 4 4 Module status and alarms Diagnostic Status Byte 0 stream IN UVIX Sensor fault on channel 1 0xB6 Sensor fault channel 1 Missing bridge on channel 1 0xB7 Missing bridge...

Страница 117: ...le solutions to any alarms can be found in the chapter Accessories par 6 5 4 Module status and alarms Diagnostic Status Byte 0 stream IN UVIX Internal error 0xA9 Internal Error Open circuit on the cha...

Страница 118: ...o ways wireless or USB This system has been implemented with a web based architecture so that information can be accessed straightforwardly using a browser Monitoring consists of displaying all the de...

Страница 119: ...all the information on the various devices and perform configuration operations or manual commands By selecting the CX4 module in Stand Alone or Valve Island configuration or individual accessory mod...

Страница 120: ...eral status of the module Not available Ok Alarm 9 Stato operativo del modulo Init initialization of the CX4 module and accessory modules Enumeration numbering of the accessory modules connected to th...

Страница 121: ...se of EtherNet IP you can configure the unique network name 14 the IP address 15 the mask 16 and the gateway 17 of the address par 7 4 Using the buttons in the bottom bar of the configuration window 1...

Страница 122: ...he subbases of the solenoid valves the measurement is made by the first subbase connected position 1 and is sent via serial communication If there are no valves connected this voltage is not displayed...

Страница 123: ...Supply voltage of the CX4 module lower than the voltage given in the specifications 8 I Omodulemappingerror thiscanoccurifthepositionsoftheI Omoduleshavebeenchanged moving them from their original po...

Страница 124: ...nual mode you can command the modules that include outputs if present such as the solenoid valves 14 par 9 3 6 digital outputs 15 par 9 5 5 and analogue outputs 16 par 9 7 5 The history of the command...

Страница 125: ...base 2 Position of the subbase in the assigned valve island after mapping 3 Name of the accessory module family Valve 4 Solenoid valve family sub type 10 mm 16 mm 25 mm 5 Firmware version 6 Date and t...

Страница 126: ...es enabled No disabled default 12 SettheFailsafestatusforeachpilotforwhichtheFailsafehasbeenenabled Onpilotactivated Off pilot deactivated default 13 Set the behaviour of the valve failure error Coil...

Страница 127: ...formed by the pilots in position 14 and position 12 3 Percentage health status of the pilots in position 14 and position 12 4 Status of the pilots in position 14 and position 12 On Off 5 Temperature o...

Страница 128: ...ing 10 Overheating of the pilots in position 14 and position 12 11 Overcurrent of the pilots in position 14 and position 12 12 Alarm solenoid valves closed in position 14 and position 12 13 Energizati...

Страница 129: ...formation 16 cycles errors health status This op eration needs to be performed when the valve connected to the subbase is replaced and can also be performed in normal working mode You can also control...

Страница 130: ...ion assigned after mapping Name of the accessory module family Digital Input Subtype of the family of the digital input module 8 CH 16 CH Firmware version Date and time of the last transmission of the...

Страница 131: ...Low default 11 Minimum input level activation time in milliseconds filtro anti bounce defualt 0 12 Minimum input rereading time in milliseconds default 0 13 Using the buttons in the bottom bar of the...

Страница 132: ...rms of the digital input module 2 Communication alarm between the digital input module and the CX4 module 3 Configuration alarm of module parameters 4 Short circuitofatleastonedigitalinputbelongingtoa...

Страница 133: ...eration Error module error 1 2 3 4 5 6 7 8 9 9 5 2 Configuration Fromthestatusinformationpage youcanconfigurecertainoperating relatedparametersofthedigital output modules 9 10 Enable output No disable...

Страница 134: ...Chapter 9 Uvix 10 11 12 13 14 15 16 5000041281 Ver 1 0 Camozzi Automation S p A 129...

Страница 135: ...Chapter 9 Uvix 9 5 3 Variables The first tab on the details page displays the status of the digital outputs 1 attiva non attiva 1 5000041281 Ver 1 0 Camozzi Automation S p A 130...

Страница 136: ...een the digital input module and the CX4 module 3 Configuration alarm of module parameters 4 No external power supply required to power the digital outputs 5 The supply voltage is less than 4 5V 6 Cir...

Страница 137: ...odule par 9 2 5 there is a tab showing the commands to pilot the individual channels of the digital outputs 8 This tab is only visible in manual mode and if it has at least one digital output module d...

Страница 138: ...tion From the status information page you can configure certain operating related parameters of the ana logue input modules 9 Some of these parameters are specific to individual subtypes while others...

Страница 139: ...Chapter 9 Uvix 10 11 12 13 14 15 16 5000041281 Ver 1 0 Camozzi Automation S p A 134...

Страница 140: ...Chapter 9 Uvix 17 18 5000041281 Ver 1 0 Camozzi Automation S p A 135...

Страница 141: ...lspagedisplaysthevariablesmonitoredbytheanalogueinputmoduleforboth channels temperatures 1 for RTD and Thermocouples currents or voltages 2 for Voltage Current modules and voltages 3 for the Bridges 1...

Страница 142: ...n error with the internal ADC converter which measures the relevant physical quantities 7 Error in 3 3V logic supply voltage 8 Malfunction of the sensor connected to channel 2 9 Bridge sensor connecte...

Страница 143: ...er mapping 3 Name of the accessory module family Analog Output 4 Subtype of the family of the analogue output module 2 CH 5 Firmware version 6 Date and time of the last transmission of the variables b...

Страница 144: ...ue output voltage or current on channel 1 11 Type of analogue output voltage or current on channel 2 12 Enable Failsafe for channel 1 Yes enabled No disabled default 13 Enable Failsafe for channel 2 Y...

Страница 145: ...isplays the alarms of the analogue input module 2 Communication alarm between the analogue output module and the CX4 module 3 Configuration alarm during parameterization 4 Open circuit on channel 1 5...

Страница 146: ...howing the commands for piloting the analogue output channels 10 and 11 by setting the value of the output in the corresponding unit of measurement This tab is only visible in manual mode and if it ha...

Страница 147: ...UVIX Manual 9 8 1 Main page 1 Button to start up the USB Gateway and start communicating with the CX4 module 2 Button to stop communication with the CX4 module 3 Button to access the UVIX Browser int...

Страница 148: ...at can be consulted via the USB gateway you can send a mapping request to the CX4 module The Require Mapping button 9 remains pending until the next restart of the CX4 module 9 9 8 4 Firmware update B...

Страница 149: ...utable to be loaded must have the following nomenclature CX4M indicates that the device is the CX4 master of the valve island xx indicates the fieldbus type so EtherNet IP EI _0136_ indicates the firm...

Страница 150: ...pter 9 Uvix Once in Boot mode the module is ready to load the new firmware into memory using the button 14 14 Wait for the new firmware to be loaded 15 15 5000041281 Ver 1 0 Camozzi Automation S p A 1...

Страница 151: ...Chapter 9 Uvix When the new firmware programming is completed a confirmation window will be displayed 16 16 5000041281 Ver 1 0 Camozzi Automation S p A 146...

Страница 152: ...ch the valve island belongs e g Packaging Machine DevSerNum serial number of the device of 17 characters es 01302103990000035 DevType device family Cx04 DevName device name Slvld device ID 0 if is a v...

Страница 153: ...sion 2 Temperature subbase C Internal temperature of the subbase 3 Cycles coil 14 nr Pilot activation cycles 14 12 4 Cycles coil 12 5 Health status coil 14 Pilot health status 14 12 6 Health status co...

Страница 154: ...mask 9 16 Sai 1 Firmware version xx xx Firmware version of the analogue input module 2 Temperature channel 1 C Temperature measured on channel 1 for RTDs or Thermocouples 3 Voltage channel 1 mV Volta...

Страница 155: ...aging Machine 1 SlvId 0 SlvType Cx04 SlvName Packaging Machine 1 VarId 4 VarVal 239 Sending the number of activation cycles performed by the pilot in position 14 equal to 1838 cy cles of a Series D so...

Страница 156: ...d and iOS which allows you to communicate via NFC technology with the CX4 module to obtain general information on the module and on the valve island if configured as such You can also use the app for...

Страница 157: ...s of the system both in Stand Alone mode and as a Valve Island to another system with a CX4 module compatible with the same fieldbus 1 2 3 You can also access other pages of the app via the icons at t...

Страница 158: ...ce family Series CX4 2 Subtype of the CX4 module family Stand alone D1 D2 D4 e D5 3 Firmware version 4 Status of the WiFi connection Yes WiFi module present No no WiFi module 5 Type of fieldbus EtherN...

Страница 159: ...ress of the WiFi module 2 IP version of the WiFi connection 3 Name of the WiFi network to which the device is connected 4 WiFi network password 5 FEP address to which the devices are connected 6 FEP p...

Страница 160: ...he name of the fieldbus 1 and also the name of the device on the network 2 the IP address 3 the mask 4 and the gateway 5 of the address These parameters are configurable par v using the write button 6...

Страница 161: ...lablepage intheapp youcanrequestanewsystemmappingusingthebuttonRequire 1 Once the request has been made it remains pending the button will change to Pending 2 until the next restart of the CX4 module...

Страница 162: ...4 info camozzi com www camozzi com Product Certification National and International Directives Regulations and Standards productcertification camozzi com Technical assistance Technical information Pro...

Страница 163: ...Italy P IVA IT 03207930177 OPERATIONAL HEADQUARTERS Via Eritrea 20 I 25126 Brescia Italy Tel 39 03037921 Info camozzi com www camozzi com Technical assistance Tel 39 030 3792790 service camozzi com Pr...