Instruction and Maintenance Rules for:

Float level indicator CLR20

R

S.a.s. di Guazzetti Giovanni e C.

COSTRUZIONI  MECCANICHE  ELETTRICHE

0948

R

Via dell'Industria 12 - 12/A - 42025 CAVRIAGO - RE - Italy

Tel.: 0522/942641 - 0522/941172

www.camlogic.it

e-mail: [email protected]

STANDARD FEATURES

The 

CLR20

 is a sensor for the detection of level thresholds on any type of liquid.

The operating principle is based on a permanent magnet (encapsulated inside the 
oat) and frictionless reed contacts.

-

Signal output: SPST (alternatively, NO or NC contact), up to 3 intervention points);

-

MAX switch power*: 80 VA

-

MAX switch voltage*: 250V AC/DC

-

MAX switch current*: 1.3 A

* all indications are for resistive loads only

2

-

Cable size: 2x1mm  (AWG17) / 150°C / L=600 mm

-

Connection to process: G 3/8 BSPP

-

Process temperature: -10 ... +70 °C

-

MAX pressure:  15 bar

-

Materials: ow EN1.4571 (AISI 316Ti), body EN1.4401 (AISI 316)

-

Mounting type: internal, vertically ±30° / horizontally for the curved version

3

-

Minimum uid density: 0,7 Kg/dm

-

Length: from 85 to 2000 mm

SAFETY RULES

All the operations described in this documentation must be carried out only by qualied personnel, authorized by the plant manager, 
applying the appropriate safety precautions to reduce risk of re, electric shock or injury.
Operational safety of the appliance is only guaranteed if used in compliance with regulations, in accordance with the instructions for use 
and any additional instructions. Arbitrary transformations or modications are strictly prohibited. In case of improper use, the appliance 
can be a source of dangers associated with the specic application, or damage to the plant, following incorrect assembly or adjustment.
Check that the power supply system complies with the regulations, with built-in automatic protection switch.
Any inspection, cleaning, maintenance, change or replacement of parts must be carried out with the indicator unpowered and plug 
disconnected from the power supply.

INSTALLATION

Before installation, carry out a visual check of the equipment to make sure 
that it has not suffered any damage during transport or storage.
If the control reveals anomalies, the product must be sent to the manufacturer 
to restore efciency.
The CLR20 indicator must be installed inside the tank, in a vertical position (A) 
with a maximum error of ± 30 degrees, or in a horizontal position (C) for the 
curved version only. Make sure that there are no external magnetic elds that 
could alter the operation of the reed.

L1

L1

L2

L1

MAX

MIN

A

B

C

NO

NC

NO

NC

NO

NC

NO

NC

ELECTRICAL CONNECTION

Disconnect  the  power  supply  before  proceeding  with  the  electrical 
connection  of  the  device.  For  voltages  above  50V,  make  sure  that  the 
indicator is grounded correctly. In the case of tanks of insulating material, 
always connect the indicator body to the ground with a suitable eyelet (* not 
supplied) screwed under the external nut.
Also available in version with M12 connector (for voltages up to MAX 150V).

OPERATION

The rising level of a liquid causes the oat to rise, which runs vertically guided 
by the body of the indicator. When the permanent magnet, encapsulated in the 
oat,  comes  in  the  proximity  of  the  reed  contact,  it  causes  it  to  close  by 
switching the state of the signal circuit.
The  indicator  does  not  require  external  power  sources.  To  reverse  the 
operating mode, remove the stop ring at the end and reverse the oat.
The indication stamped on the sphere towards the threaded end indicates the 
operating mode: NC = closed circuit in the absence of liquid; NO = open 
circuit in the absence of liquid.

MAINTENANCE

Periodically check that there are no solid deposits (e.g. limescale) on the central rod of the indicator body that could obstruct the 
movement of the oat. The electrical components inside the indicator do not require any maintenance.