EMC_SPEC018_C2.doc
Rev. D
–
2020 05 19
8/44
Install & Operating Manual
CamSafe
Temperature Limitations
From the technical characteristics of materials employed (paint & plastic parts), it is safe to say that
CamSafe housings are fully functional for the same temperature range as the most common filter cell
ranges, i.e. 60°C maximum for continuous use.
PLEASE NOTE:
HOT process air and/or environment
Under no circumstances should a housing be continuously exposed to
temperatures > 90°C.
PLEASE NOTE:
COLD process air
Process air temperatures <4°C would require an insulated housing to avoid
condensation.
This option is NOT available ytd due to the morphology of the housing body.
The following materials are used in CamSafe filter housings.
➔
Max. temperatures are values for permanent exposure.
Illustration
Name
Material(s)
Temp.
Max
[°C]
Housing Body & Door
Weldment
Housing body & door
(a) 1.0038 (S235JRG2)
(b) SS 1.4301 (X5CrNi18-10)
(c) SS 1.4404 (X5CrNiMo17-12-2)
( >250 )
-
Screws & Nuts & Fittings
(a) Zn8C
(b) SS A2
(c) SS A4
( >250 )
-
Powder Coat
Primer
Topcoat
Epoxy
Polyester
(
<=90
)
-
Door Gasket
Chloropren Rubber 40 Shore A
(
<=100
)
-
Door Gasket Tape
Acrylic Adhesive
(
<=120
)
Star Button
DIN 6336-KU-63-M10-K-MS
Phenolic Resin
PF31
(
<=140
)
-
Stickers
PVC
(
<=60
)