![Camfil CamSafe Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/camfil/camsafe/camsafe_installation-and-operating-manual_487851015.webp)
EMC_SPEC018_C2.doc
Rev. D
–
2020 05 19
15/44
Install & Operating Manual
CamSafe
8.2
Assembly of Horizontal Airflow Configurations
Subject to order conditions and/or transport limitations, components of most larger horizontal-flow
configurations may be shipped separately.
Airtight assembly is required, instruction for module / gasket assembly from General Assembly
fully apply.
Precautions :
Horizontal flow involves temporarily cantilevered modules during assembly.
Configurations may reach important height.
Consult drawings for dimensions, weight and centers of gravity.
Prepare wooden or plastic shims for temporary alignment support.
Respect applicable work safety rules for access, manipulation and static support.
Place 1
st
collector
on the support stand.
Position collector
and secure against tipping over.
For non-adhesive gaskets, place
small strips of double-sided tape
on the collector flange(s).
Place gasket(s) on the flange(s),
aligning flange and gasket holes.
Place 1
st
housing,
aligning flange holes.
Use housing-collector bolts to
securely link to the support stand.
Tighten nuts, do not block yet
at this point.
13
M8