C-3
Scanner
®
2000 microEFM
Appendix C
Table C.1—Scanner 2000 microEFM Specifications (Fieldbus Devices Only)
F
oundation
™ Fieldbus
Fieldbus power/communications port on fieldbus interface board
Fieldbus module contains 1 resource block, 1 transducer block, and 4
analog input blocks
Device is capable of being a link master and a link active scheduler
Note Standard (non-fieldbus) Scanner 2000 models have two COM ports on the Scanner 2000 main board,
but on Foundation™ fieldbus models, COM2 is dedicated to communication with the fieldbus inter-
face board and is not available for other uses.
Installing the Scanner 2000
The following customer-supplied equipment is recommended for installating a Scanner 2000 in a fieldbus
network:
•
host computer
•
power supply
• linking device (may be combined with the host system)
•
terminators
•
Type A single pair shielded twisted cable for the power connection
The Scanner 2000 has the capability to be a link master and a link active scheduler for controlling
communication on the bus.
Control System Components
In its simplest form, a
F
oundation
™ fieldbus control system has two tiers: a host network and a field network.
The instruments that make up the field network connect to the host level workstations via a linking device.
The field network consists of one or more segments, with a terminator at each end. Field devices receive their
power and their ability to communicate with other devices and the host from the fieldbus network. Up to 32
devices can be connected to a single network.
Содержание Scanner 2000 microEFM
Страница 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Страница 26: ...26 Section 1 Scanner 2000 microEFM ...
Страница 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Страница 106: ...B 2 Appendix B Scanner 2000 microEFM ...
Страница 188: ...E 10 Appendix D Scanner 2000 microEFM ...
Страница 190: ...R U S S I A 603 5569 0501 ms kl c a m com ...