Event Handling
1. Arm/Disarm
Arm/Disarm
Arm/Disarm input is used for enhancing security level of the surveillance area. This input
introduces the concept of 3 zone types of alarm, fire zone, normal and entry exit zone.
Armed
If the system is armed, alarm sensor in normal zone type can be triggered immediately if
someone triggers the sensor. It is usually used when there is no operator at surveillance area.
Disarmed
If the system is disarmed, alarm events detected from sensors will not result in an alarm except
the fire zone type alarm and arm/disarm tamper. If there are operators at surveillance area, it is
usually disarmed.
Arm/Disarm Tamper Type
Arm/Disarm tamper event triggers if someone cuts the wire between the arm/disarm input and
the video recording server. This event can be triggered immediately no matter which the zone is.
Arm/Disarm tamper type has choice of none, SEOL and DEOL.
Arm State
The arm/disarm input circuit type is normal close (NC). When the state of the circuit is close, it
indicates disarm of
RX
. Otherwise, when the state of the circuit is open, it indicates
arm of
RX
. The arm/disarm input circuit type is normal open (NO). When the state
of the circuit is open, it indicates disarm of
RX
. Otherwise, when the state of the
circuit is close, it indicates arm of
RX
.
Physical Configuration for Arm/Disarm
The arm/disarm input and ground of
RX
video recording server needs to connect to
a control unit which is commonly a switch or password panel for arm/disarm input.