Before proceeding with the installation, it is necessary to:
- provide for suitable omnipolar disconnection device with more than 3 mm between contacts to section power supply;
- connections inside the case made for protection circuit continuity are allowed as long as they include additional insulation
with respect to other internal drive parts;
- make sure the mains voltage is disconnected.
Make sure all tools and materials necessary are within reach to install the edge in maximum safety, according to regulations in
force. The following figure illustrates the minimum equipment for the installer.
5.3 Cable list and minimun thickness
5.2 Tools and materials
Connections
Type of cable
Length of
cable 1<10 m
Length of
cable 10<20 m
Length of
cable 20<30 m
230V 2F power supply line
FROR CEI 20-22
CEI EN 50267-2-1
3G 1,5mm²
3G 2,5mm²
3G 4mm²
24V motors
2 x 1mm²
2 x 1,5mm²
2 x 2,5mm²
230V fl ashing lamp
2 x 0,5mm²
2 x 1mm²
2 x 1,5mm²
24V fl ashing lamp
2 x 0,5mm²
2 x 1mm²
2 x 1,5mm²
230V courtesy / cycle light
3G 0,5mm²
3G 1mm²
3G 1,5mm²
24V power supply accessory
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
24V pilot light
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
24V “in motion” output
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
Safety contacts
2 x 0,5mm²
2 x 0,5mm²
2 x 0,5mm²
N.O./N.C. control button
2 x 0,5mm²
2 x 0,5mm²
2 x 0,5mm²
End stop
3 x 0,5mm²
3 x 1mm²
3 x 1,5mm²
Command 2nd combined motor
1 x 0,5mm²
1 x 0,5mm²
1 x 1mm²
Antenna connection
RG58
max. 50 m
Encoder connection
2402C 22AWG shielded cable
max. 30 m
N.B.: An evaluation of the size of the cables with lengths other than the data in the table must be made based on the effective
absorption of the connected devices, according to the instructions indicated by the CEI EN 60204-1 standards.
For connections that require several loads on the same line (sequential), the size given on the table must be re-evaluated based
on actual absorption and distances.
5 Installation
5.1 Preliminary checks