4.1 Command board

1 Legend

 

This symbol indicates sections to be read with particular care.

 

This symbol indicates sections concernig safety

  

This symbol indicates notes to communicate to users.

Fully designed and built by CAME CANCELLI AUTOMATICI S.p.A. Guaranteed for 24 months unless tampered with.
The command board is powered at 230V A.C. on the L-N terminals with 50÷60 Hz frequency and is protected in input with 3.15A 
fuses.
A 2A fuse protects the low-voltage (24V) command devices.
630mA control unit fuse. 10A motor fuse. 
The overall rated power of the 24V accessories must not exceed 40 W.

The photoelectric cells may be connected and pre-set for:
- Re-opening during closing phases: if the photocells identify an obstacle while the gate is closing, they will reverse the direc-
tion of movement until the gate is completely open;
- Total stop: stops the bar with consequent exclusion of the automatic closing cycle; pushbuttons or transmitters must be used 
to resume movement.

The board also integrates and independently manages a safety function which is sensitive to obstacles (amperometric device) 
that: 
during opening: the bar stops;
during closing: the bar reverses its direction until it opens completely; automatic closure is thus activated. 
 

Caution! after three consecutive direction reversals, the bar will remain up and automatic closure will be discontinued. 

To close the gate, use the radio remote control or the push-button.

Other selectable functions:
- Automatic closure. The automatic closure timer self-powers at the end stop in opening. The set time can be adjusted and is 
also subject to modifi cations due to the intervention of additional safety features. This does not happen following a complete 
“stop” command or if there be a power cut;
- Immediate closure: The bar lowers automatically after the vehicle has exceeded the range of action of the safety devices; 
- Obstacle detection: this function voids every command if an obstacle is detected by the photoelectric cells (connected to any 
safety function);
- Maintained action operations: barrier operation while keeping the pushbutton pressed (it excludes the radio transmitter ope-
ration);
- Pre-fl ashing during opening and closing: after an opening or closing command, the fl ashing lamp connected to 10-E, fl ashes 
for 5 seconds before the manoeuvre begins;
- Slave operations: in the case of two barriers working in pairs;

4 Description

2.1 Destination

The following standard were complied with for this product: EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453.

2 Destination and limits of use

The electronic command board was designed for specific use in automatic GARD 4 and GARD 8 series barriers with 24V gear 
motors; inserted into the container fitted with a transformer with IP54 protection level, 230V power supply with 50÷60 Hz 
frequency.

 

Uses other than the ones described above and installations using methods other than those shown in this technical 

manual are considered prohibited.

3 Standard followed

2.2 Limits of use

Comply with the cable cross-sections recommended in the table under chapter 5.3

“IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION”

“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”

“THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS”

Содержание ZL38

Страница 1: ...ZL38 AUTOMAZIONE PER CHIUSURA INDUSTRIALE INSTALLATION MANUAL COMMAND BOARD FOR BARRIERS WITH 24V MOTOR...

Страница 2: ...automatic closure timer self powers at the end stop in opening The set time can be adjusted and is also subject to modifications due to the intervention of additional safety features This does not hap...

Страница 3: ...ction that increases the braking action of the barrier Type of command open close or opening only Settings automatic closure time adjustment amperometric sensitivity Optional accessories flashing dome...

Страница 4: ...OR CEI 20 22 CEI EN 50267 2 1 3G 1 5mm 3G 2 5mm 3G 4mm 24V motors 2 x 1mm 2 x 1 5mm 2 x 2 5mm 230V flashing lamp 2 x 0 5mm 2 x 1mm 2 x 1 5mm 24V flashing lamp 2 x 0 5mm 2 x 1mm 2 x 1 5mm 230V courtesy...

Страница 5: ...s or three in the case of the G4040 of the cover of the container located on the upper part of the automation 2 Insert the card into the container and fasten it with the screws supplied ZL 38 ZL 38 1...

Страница 6: ...amp 24V 3W max Contact N C of immediate closing Microswitch connection slowdown during opening Microswitch connection slowdown during closing Antenna connection 04 4 2 DIP 3 OFF Flashing movement indi...

Страница 7: ...emote control function disabled activated 5 ON Pre flashing activated during opening and closing 6 ON Obstacle presence detection activated 6 OFF deactivated 7 ON Slave motor driven function activated...

Страница 8: ...ted as the Master execute all the wiring connections see page 6 the instal lation procedure for remote control settings and regulations On the command board designated as the Slave position the dip 7...

Страница 9: ...ion on circuit card AF43S as shown on the sheet 6 1 Prepare the radio board AF 6 Installation procedure of the transmitter for remote control Standard encoding procedure T262M T264M T2622M T302M T304M...

Страница 10: ...be carried out whilst keeping the jumpers po sitioned for channels 1 and 2 as per fig A see fig B for any subsequent settings on different channels TOP T262M T302M FIG A FIG B 0 0 0 0 T264M T304M 0 0...

Страница 11: ...2 CH3 CH4 CH1 CH2 CH3 CH4 TOP T434M T314M 0 0 0 0 C set code only P1 CH1 P2 CH2 P3 CH3 P4 CH4 TOP T432S T432SA T434MA T432NA T434NA see instructions on pack TAM T432 T434 T438 TAM432SA see instruction...

Страница 12: ...ed to signal memorization N B if the code needs to be changed repeat the sequence described above Flashing LED Lit LED Radio board 2 Insert the inspection door and close it 1 After making the adjustme...

Страница 13: ...acturer s warranty MANUFACTURER S DECLARATION As per Enclosure II B of Machinery Directive 98 37 CE Enclosed with the technical documentation the original copy of the Declaration is available on reque...

Отзывы: