P
age
29
- Manual
FA01568-EN
- 07/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Advanced operation
The advanced operation modes can be selected from the THermo app only.
Display mode
You can choose between a simplifi ed view
(temperature setpoint, internal temperature
detected and system status) and a full
view.
To switch from the simplifi ed to the full
view, press one of the navigation keys.
Thermal control algorithm
Thermal differential algorithm
A
B
C
For systems with diff erent thermal inertias.
The thermal diff erential can be adjusted
between 0.1°C and 1°C.
X
Time
Y
Temperature
A
= Se diff erential
B
= Setpoint
C
= Setpoint - diff erential