background image

Pa

g.

 

2

  - M

an

ua

l c

od

e: 

11

9

D

U

8

5

E

N

11

9

D

U

8

5

E

N

 ver

2

  

2  

0

4

/2

0

16  © C

A

M

E S

.p.

A

. - T

he d

at

a a

nd i

nf

or

m

at

io

n r

ep

or

te

d i

n t

hi

s i

ns

ta

lla

tio

n m

an

ua

l a

re s

us

ce

pt

ib

le t

o c

ha

ng

e a

t a

ny t

im

e a

nd w

ith

ou

t o

bli

ga

tio

n o

n C

A

M

E S

.p.

A

. t

o n

ot

if

y u

se

rs

.

Danger of hand crushing 

Danger! High voltage. 

No transiting while maneuvering 

Danger of foot crushing 

P

REMISE

• E

MPLOY

 

THIS

 

PRODUCT

 

ONLY

 

FOR

 

THE

 

USE

 

FOR

 

WHICH

 

IT

 

WAS

 

EXPRESSLY

 

MADE

. A

NY

 

OTHER

 

USE

 

IS

 

DANGEROUS

. C

AME

 S.

P

.A. I

S

 

NOT

 

LIABLE

 

FOR

 

ANY

 

DAMAGE

 

CAUSED

 

BY

 

IMPROPER

WRONGFUL

 

AND

 

UNREASONABLE

 

USE

 • 

KEEP

 

THESE

 

WARNINGS

 

TOGETHER

 

WITH

 

THE

 

INSTALLATION

 

AND

 

OPERATION

 

MANUALS

 

THAT

 

COME

 

WITH

 

THE

 

OPERATOR

B

EFORE

 

INSTALLING

(C

HECKING

 

WHAT

'

S

 

THERE

IF

 

YOUR

 

EVALUATION

 

IS

 

NEGATIVE

DO

 

NOT

 

PROCEED

 

BEFORE

 

HAVING

 

COMPLIED

 

WITH

 

ALL

 

SAFETY

 

REQUIREMENTS

• C

HECK

 

THAT

 

THE

 

AUTOMATED

 

PARTS

 

ARE

 

IN

 

GOOD

 

MECHANICAL

 

ORDER

THAT

 

THE

 

OPERATOR

 

IS

 

LEVEL

 

AND

 

ALIGNED

AND

 

THAT

 

IT

 

OPENS

 

AND

 

CLOSES

 

PROPERLY

. M

AKE

 

SURE

 

YOU

 

HAVE

 

SUITABLE

 

MECHANICAL

 

STOPS

 • 

IF

 

THE

 

OPERATOR

 

IS

 

TO

 

BE

 

INSTALLED

 

AT

 

A

 

HEIGHT

 

OF

 

OVER

 

2.5 M 

FROM

 

THE

 

GROUND

 

OR

 

OTHER

 

ACCESS

 

LEVEL

MAKE

 

SURE

 

YOU

 

HAVE

 

ANY

 

NECESSARY

 

PROTECTIONS

 

AND

/

OR

 

WARNINGS

 

IN

 

PLACE

 • 

IF

 

ANY

 

PEDESTRIAN

 

OPENINGS

 

ARE

 

FITTED

 

INTO

 

THE

 

OPERATOR

THERE

 

MUST

 

ALSO

 

BE

 

A

 

A

 

SYSTEM

 

TO

 

BLOCK

 

THEIR

 

OPENING

 

WHILE

 

THEY

 

ARE

 

MOVING

 • 

MAKE

 

SURE

 

THAT

 

THE

 

OPENING

 

AUTOMATED

 

DOOR

 

OR

 

GATE

 

CANNOT

 

ENTRAP

 

PEOPLE

 

AGAINST

 

THE

 

FIXED

 

PARTS

 

OF

 

THE

 

OPERATOR

 • 

DO

 

NOT

 

INSTALL

 

THE

 

OPERATOR

 

UPSIDE

 

DOWN

 

OR

 

ONTO

 

ELEMENTS

 

THAT

 

COULD

 

YIELD

 

AND

 

BEND

. I

F

 

NECESSARY

ADD

 

SUITABLE

 

REINFORCEMENTS

 

TO

 

THE

 

ANCHORING

 

POINTS

 • 

DO

 

NOT

 

INSTALL

 

DOOR

 

OR

 

GATE

 

LEAVES

 

ON

 

TILTED

 

SURFACES

 • 

MAKE

 

SURE

 

ANY

 

SPRINKLER

 

SYSTEMS

 

CANNOT

 

WET

 

THE

 

OPERATOR

 

FROM

 

THE

 

GROUND

 

UP

 • 

MAKE

 

SURE

 

THE

 

TEMPERATURE

 

RANGE

 

SHOWN

 

ON

 

THE

 

PRODUCT

 

LITERATURE

 

IS

 

SUITABLE

 

TO

 

THE

 

CLIMATE

 

WHERE

 

IT

 

WILL

 

BE

 

INSTALLED

 • 

FOLLOW

 

ALL

 

INSTRUCTIONS

 

AS

 

IMPROPER

 

INSTALLATION

 

MAY

 

RESULT

 

IN

 

SERIOUS

 

BODILY

 

INJURY

 • 

IT

 

IS

 

IMPORTANT

 

TO

 

FOLLOW

 

THESE

 

INSTRUCTIONS

 

FOR

 

THE

 

SAFETY

 

OF

 

PEOPLE

. K

EEP

 

THESE

 

INSTRUCTIONS

I

NSTALLING

• S

UITABLY

 

SECTION

 

OFF

 

AND

 

DEMARCATE

 

THE

 

ENTIRE

 

INSTALLATION

 

SITE

 

TO

 

PREVENT

 

UNAUTHORIZED

 

PERSONS

 

FROM

 

ENTERING

 

THE

 

AREA

ESPECIALLY

 

MINORS

 

AND

 

CHILDREN

 • 

BE

 

CAREFUL

 

WHEN

 

HANDLING

 

OPERATORS

 

THAT

 

WEIGH

 

OVER

 20 

KG

. I

F

 

NEED

 

BE

USE

 

PROPER

 

SAFETY

 

HOISTING

 

EQUIPMENT

 • 

ALL

 

OPENING

 

COMMANDS

 (

THAT

 

IS

BUTTONS

KEY

 

SWITCHES

MAGNETIC

 

READERS

AND

 

SO

 

ON

)  

MUST

 

BE

 

INSTALLED

 

AT

 

LEAST

 1.85 M 

FROM

 

THE

 

PERIMETER

 

OF

 

THE

 

GATE

'

S

 

WORKING

 

AREA

OR

 

WHERE

 

THEY

 

CANNOT

 

BE

 

REACHED

 

FROM

 

OUTSIDE

 

THE

 

GATE

A

LSO

ANY

 

DIRECT

 

COMMANDS

 (

BUTTONS

TOUCH

 

PANELS

AND

 

SO

 

ON

MUST

 

BE

 

INSTALLED

 

AT

 

LEAST

 1.5 M 

FROM

 

THE

 

GROUND

 

AND

 

MUST

 

NOT

 

BE

 

REACHABLE

 

BY

 

UNAUTHORIZED

 

PERSONS

 

• 

ALL

 

MAINTAINED

 

ACTION

 

COMMANDS

MUST

 

BE

 

FITTED

 

IN

 

PLACES

 

FROM

 

WHICH

 

THE

 

MOVING

 

GATE

 

LEAVES

 

AND

 

TRANSIT

 

AND

 

DRIVING

 

AREAS

 

ARE

 

VISIBLE

 • 

APPLY

IF

 

MISSING

A

 

PERMANENT

 

SIGN

 

SHOWING

 

THE

 

POSITION

 

OF

 

THE

 

RELEASE

 

DEVICE

 • 

BEFORE

 

DELIVERING

 

TO

 

THE

 

USERS

MAKE

 

SURE

 

THE

 

SYSTEM

 

IS

 

EN

 12453 

STANDARD

 

COMPLIANT

 (

REGARDING

 

IMPACT

 

FORCES

), 

AND

 

ALSO

 

MAKE

 

SURE

 

THE

 

SYSTEM

 

HAS

 

BEEN

 

PROPERLY

 

ADJUSTED

 

AND

 

THAT

 

ANY

 

SAFETY

PROTECTION

 

AND

 

MANUAL

 

RELEASE

 

DEVICES

 

ARE

 

WORKING

 

PROPERLY

 • 

APPLY

 

WARNING

 

SIGNS

 

(

SUCH

 

AS

 

THE

 

GATE

'

S

 

PLATE

WHERE

 

NECESSARY

 

AND

 

IN

 

A

 

VISIBLE

 

PLACE

 

S

PECIAL

 

USER

-

INSTRUCTIONS

 

AND

 

RECOMMENDATIONS

 

• K

EEP

 

GATE

 

OPERATION

 

AREAS

 

CLEAN

 

AND

 

FREE

 

OF

 

ANY

 

OBSTRUCTIONS

. M

AKE

 

SURE

 

THAT

 

THE

 

PHOTOCELLS

 

ARE

 

FREE

 

OF

 

ANY

 

OVERGROWN

 

VEGETATION

 

AND

 

THAT

 

THE

 

OPERATOR

'

S

 

AREA

 

OF

 

OPERATION

 

IS

 

FREE

 

OF

 

ANY

 

OBSTRUCTIONS

 • 

DO

 

NOT

 

ALLOW

 

CHILDREN

 

TO

 

PLAY

 

WITH

 

FIXED

 

COMMANDS

OR

 

TO

 

LOITER

 

IN

 

THE

 

GATE

'

S

 

MANEUVERING

 

AREA

. K

EEP

 

ANY

 

REMOTE

 

CONTROL

 

TRANSMITTERS

 

OR

 

ANY

 

OTHER

 

COMMAND

 

DEVICE

 

AWAY

 

FROM

 

CHILDREN

TO

 

PREVENT

 

THE

 

OPERATOR

 

FROM

 

BEING

 

ACCIDENTALLY

 

ACTIVATED

. • T

HE

 

APPARATUS

 

MAY

 

BE

 

USED

 

BY

 

CHILDREN

 

OF

 

EIGHT

 

YEARS

 

AND

 

ABOVE

 

AND

 

BY

 

PHYSICALLY

MENTALLY

 

AND

 

SENSORIALLY

 

CHALLENGED

 

PEOPLE

OR

 

EVEN

 

ONES

 

WITHOUT

 

ANY

 

EXPERIENCE

PROVIDED

 

THIS

 

HAPPENS

 

UNDER

 

CLOSE

 

SUPERVISION

 

OR

 

ONCE

 

THEY

 

HAVE

 

BEEN

 

PROPERLY

 

INSTRUCTED

 

TO

 

USE

 

THE

 

APPARATUS

 

SAFELY

 

AND

 

ABOUT

 

THE

 

POTENTIAL

 

HAZARDS

 

INVOLVED

. C

HILDREN

 

MUST

 

NOT

 

PLAY

 

WITH

 

THE

 

APPARATUS

. C

LEANING

 

AND

 

MAINTENANCE

 

BY

 

USERS

 

MUST

 

NOT

 

BE

 

DONE

 

BY

 

CHILDREN

UNLESS

 

PROPERLY

 

SUPERVISED

 • 

FREQUENTLY

 

CHECK

 

THE

 

SYSTEM

 

FOR

 

ANY

 

MALFUNCTIONS

 

OR

 

SIGNS

 

OF

 

WEAR

 

AND

 

TEAR

 

OR

 

DAMAGE

 

TO

 

THE

 

MOVING

 

STRUCTURES

TO

 

THE

 

COMPONENT

 

PARTS

ALL

 

ANCHORING

 

POINTS

INCLUDING

 

CABLES

 

AND

 

ANY

 

ACCESSIBLE

 

CONNECTIONS

. K

EEP

 

ANY

 

HINGES

MOVING

 

JOINTS

 

AND

 

SLIDE

 

RAILS

 

PROPERLY

 

LUBRICATED

 • 

PERFORM

 

FUNCTIONAL

 

CHECKS

 

ON

 

THE

 

PHOTOCELLS

 

AND

 

SENSITIVE

 

SAFETY

 

EDGES

EVERY

 

SIX

 

MONTHS

. T

O

 

CHECK

 

WHETHER

 

THE

 

PHOTOCELLS

 

ARE

 

WORKING

WAVE

 

AN

 

OBJECT

 

IN

 

FRONT

 

OF

 

THEM

 

WHILE

 

THE

 

GATE

 

IS

 

CLOSING

IF

 

THE

 

OPERATOR

 

INVERTS

 

ITS

 

DIRECTION

 

OF

 

TRAVEL

 

OR

 

SUDDENLY

 

STOPS

THE

 

PHOTOCELLS

 

ARE

 

WORKING

 

PROPERLY

. T

HIS

 

IS

 

THE

 

ONLY

 

MAINTENANCE

 

OPERATION

 

TO

 

DO

 

WITH

 

THE

 

POWER

 

ON

C

ONSTANTLY

 

CLEAN

 

THE

 

PHOTOCELLS

GLASS

 

COVERS

 

USING

 

A

 

SLIGHTLY

 

WATER

-

MOISTENED

 

CLOTH

DO

 

NOT

 

USE

 

ANY

 

SOLVENTS

 

OR

 

OTHER

 

CHEMICAL

 

PRODUCTS

 

THAT

 

MAY

 

RUIN

 

THE

 

DEVICES

 

• 

IF

 

REPAIRS

 

OR

 

MODIFICATIONS

 

ARE

 

REQUIRED

 

TO

 

THE

 

SYSTEM

RELEASE

 

THE

 

OPERATOR

 

AND

 

DO

 

NOT

 

USE

 

IT

 

UNTIL

 

SAFETY

 

CONDITIONS

 

HAVE

 

BEEN

 

RESTORED

 • 

CUT

 

OFF

 

THE

 

POWER

 

SUPPLY

 

BEFORE

 

RELEASING

 

THE

 

OPERATOR

 

FOR

 

MANUAL

 

OPENINGS

 

AND

 

BEFORE

 

ANY

 

OTHER

 

OPERATION

TO

 

PREVENT

 

POTENTIALLY

 

HAZARDOUS

 

SITUATIONS

. R

EAD

 

THE

 

INSTRUCTIONS

 • 

IF

 

THE

 

POWER

 

SUPPLY

 

CABLE

 

IS

 

DAMAGED

IT

 

MUST

 

BE

 

REPLACED

 

BY

 

THE

 

MANUFACTURER

 

OR

 

AUTHORIZED

 

TECHNICAL

 

ASSISTANCE

 

SERVICE

OR

 

IN

 

ANY

 

CASE

BY

 

SIMILARLY

 

QUALIFIED

 

PERSONS

TO

 

PREVENT

 

ANY

 

RISK

 • 

IT

 

IS

 

FORBIDDEN

 

FOR

 

USERS

 

TO

 

PERFORM

 

ANY

 

OPERATIONS

 

THAT

 

ARE

 

NOT

 

EXPRESSLY

 

REQUIRED

 

OF

 

THEM

 

AND

 

WHICH

 

ARE

 

NOT

 

LISTED

 

IN

 

THE

 

MANUALS

. F

OR

 

ANY

 

REPAIRS

MODIFICATIONS

 

AND

 

ADJUSTMENTS

 

AND

 

FOR

 

EXTRAORDINARY

 

MAINTENANCE

CALL

 

TECHNICAL

 

ASSISTANCE

 • 

LOG

 

THE

 

JOB

 

AND

 

CHECKS

 

INTO

 

THE

 

PERIODIC

 

MAINTENANCE

 

LOG

A

DDITIONAL

 

SPECIAL

 

RECOMMENDATIONS

 

FOR

 

EVERYONE

 

• K

EEP

 

AWAY

 

FROM

 

HINGES

 

AND

 

MECHANICAL

 

MOVING

 

PARTS

 • 

DO

 

NOT

 

ENTER

 

THE

 

OPERATOR

'

S

 

AREA

 

OF

 

OPERATION

 

WHEN

 

IT

 

IS

 

MOVING

 • 

DO

 

NOT

 

COUNTER

 

THE

 

OPERATOR

'

S

 

MOVEMENT

 

AS

 

THIS

 

COULD

 

RESULT

 

IN

 

DANGEROUS

 

SITUATIONS

 • 

ALWAYS

 

PAY

 

SPECIAL

 

ATTENTION

 

TO

 

ANY

 

DANGEROUS

 

POINTS

WHICH

 

HAVE

 

TO

 

BE

 

LABELED

 

WITH

 

SPECIFIC

 

PICTOGRAMS

 

AND

/

OR

 

BLACK

 

AND

 

YELLOW

 

STRIPES

 • 

WHILE

 

USING

 

A

 

SELECTOR

 

SWITCH

 

OR

 

A

 

COMMAND

 

IN

 

MAINTAINED

 

ACTIONS

KEEP

 

CHECKING

 

THAT

 

THERE

 

ARE

 

NO

 

PERSONS

 

WITHIN

 

THE

 

OPERATING

 

RANGE

 

OF

 

ANY

 

MOVING

 

PARTS

UNTIL

 

THE

 

COMMAND

 

IS

 

RELEASED

 • 

THE

 

GATE

 

MAY

 

MOVE

 

AT

 

ANY

 

TIME

 

AND

 

WITHOUT

 

WARNING

 • 

ALWAYS

 

CUT

 

OFF

 

THE

 

POWER

 

SUPPLY

 

BEFORE

 

PERFORMING

 

ANY

 

MAINTENANCE

 

OR

 

CLEANING

.

WARNING!

important safety instructions:

READ CAREFULLY!

Содержание AX302304

Страница 1: ...INSTALLATION MANUAL AX302304 AX402306 AX412306 AX71230 AUTOMATION FOR SWING GATES 119DU85EN English EN ...

Страница 2: ... IN A VISIBLE PLACE SPECIAL USER INSTRUCTIONS AND RECOMMENDATIONS KEEP GATE OPERATION AREAS CLEAN AND FREE OF ANY OBSTRUCTIONS MAKE SURE THAT THE PHOTOCELLS ARE FREE OF ANY OVERGROWN VEGETATION AND THAT THE OPERATOR S AREA OF OPERATION IS FREE OF ANY OBSTRUCTIONS DO NOT ALLOW CHILDREN TO PLAY WITH FIXED COMMANDS OR TO LOITER IN THE GATE S MANEUVERING AREA KEEP ANY REMOTE CONTROL TRANSMITTERS OR AN...

Страница 3: ... to read the section with particular care This symbol tells you that the sections concern safety issues This symbol tells you what to say to the end users 2 Intended use and application The AXO operator is designed to automate swing gates used in residential or condominium settings The use of this product for purposes other than those described above and installation executed in a manner other tha...

Страница 4: ... 4 4 Dimensions GEARMOTOR AX71230 Control board power supply 230V AC 50 60Hz Motor power supply 230V AC 50 60Hz Max draw 1 5A Power 175W Adjustable thrust 500 4500N Opening time 90 40s Duty cycle 30 Protection rating IP44 Motor s thermal protection 150 C GEARMOTOR AX402306 AX412306 Control board power supply 230V AC 50 60Hz Motor power supply 230V AC 50 60Hz Max draw 1 5A Power 175W Adjustable thr...

Страница 5: ...able 20 30 m Control panel power supply 230V FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 2 5 mm2 3G x 4 mm2 Motor power supply 230V 4G x 1 mm2 4G x 1 5 mm2 4G x 2 5 mm2 Flashing light 2 x 0 5 mm2 2 x 1 mm2 2 x 1 5 mm2 Photocell transmitters 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 Photocell receivers 4 x 0 5 mm2 4 x 0 5 mm2 4 x 0 5 mm2 Accessories power supply 2 x 0 5 mm2 2 x 0 5 mm2 2 x 1 mm2 Co...

Страница 6: ... number of tubes depends on the type of system and accessories employed The following illustrations are only examples given that the space available for anchoring the operator and accessories may vary from gate to gate It is up to the installer thus to choose the most suitable solution 5 5 Installing the operator 1 AXO operator 2 Control panel 3 Reception antenna 4 Flashing light 5 Selector switch...

Страница 7: ...ich you will secure the gate bracket secure the bracket to the pillar and make sure the quotas shown in the table below are met Note by increasing measure B the opening angle and gate speed are reduced while the gearmotor thrust is increased By increasing the measure A the opening angle and gate speed are increases while the gearmotor thrust is decreased Gate leaves of up to 7 m Opening angle A mm...

Страница 8: ...o the pillar bracket s hole The bracket has holes that allow the opening angle to be changed Secure the tail joint to the bracket Note on non metal gate leaves assemble and weld the two parts of the bracket and secure them with proper screws Secure the tail joint to the bracket Tail joint Bushing Screw M8 x 35 Nut UNI 7474 M8 Weld the gate bracket to the gate leaf making sure the quotas shown in t...

Страница 9: ...al stop place it up against the attachment pin then secure it Closing mechanical stop Attachment pin Open the gate leaf and insert the pin into the gate bracket and secure it using a washer and nut Gate bracket Release the gearmotor see paragraph on manual release completely open the gate leaf loosen the nuts of the opening mechanical stop and position it up against the attachment pin then secure ...

Страница 10: ... the small door that protects the release insert the tri lobed key and turn it 5 6 Manual release of the gearmotor For the electrical connection procedures use the junction box and branching boxes 5 7 Connecting to the control panel Power 230V a c 50 60 Hz Connecting the 230V a c delayed closing gearmotor Connecting the 230V a c delayed opening gearmotor ZM3E Control panel yellow green blue black ...

Страница 11: ...e 1 are met Weld or secure with proper screws the gate bracket making sure the E quota is met as shown in table 1 Finally secure the gearmotor to the brackets with the issued screws and washers 5 8 Outward opening installation Opening A B E 90 130 130 800 Pillar bracket Extra bracket Gate bracket For AX71230 gearmotors directly secure the standard issue bracket to the pillar without using the supp...

Страница 12: ...n the diagram Fully open the gate leaf place the mechanical stop against it with the pin attachment and fix it in place Fully close the gate leaf place the mechanical stop against it with the pin attachment and fix it in place Opening mechanical stop Attachment pin Closing mechanical stop Attachment pin Power 230V a c 50 60 Hz Delayed closing action Delayed opening action white brown green brown b...

Страница 13: ...ed ______________________________________________________________________________________ __________________________________________________________________________________________________ ______________________________________________________________________________________________ Extraordinary maintenance Extraordinary maintenance Before doing any maintenance cut off the power supply to prevent...

Страница 14: ... cables can be considered to be solid urban waste They may be recycled at authorised firms Other components electrical circuit board remote control batteries etc may contain hazardous waste They must thus be removed and turned in to licensed firms for their disposal Before acting always check the local laws on the matter DO NOT DISPOSE OF IN NATURE 8 Phasing out and disposal MALFUNCTIONS POSSIBLE ...

Страница 15: ...Manual code 119DU85EN 119DU85EN ver 2 2 04 2016 CAME S p A The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME S p A to notify users ...

Страница 16: ...taly 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English English Manual code 119DU85EN 119DU85EN ver 2 2 04 2016 CAME S p A The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME S p A to notify users ...

Отзывы: