ZLX24MA

ZLX24MR

INSTALLATION MANUAL

FA01554-EN

EN

English

Содержание 801QA-0050

Страница 1: ...ZLX24MA ZLX24MR INSTALLATION MANUAL FA01554 EN EN English...

Страница 2: ...led and quali ed personnel and in full compliance with the regulations in force The device must be installed wired connected and tested according to good professional practice in compliance with the s...

Страница 3: ...ntrol this must be installed at a minimum height of 1 5 m from the ground and must not be accessible to the public If not already present apply a permanent tag that describes how to use the manual rel...

Страница 4: ...ging materials cardboard plastic etc can be disposed of easily as solid urban waste separated for recycling Before dismantling and disposing of the product please always check the local laws in force...

Страница 5: ...ology BUS CXN 2 safety inputs and memory space for up to 250 users 801QA 0070 ZLX24MR Multifunction control panel with 120 VAC power supply for 24 V swing gates with two leaves with programming displa...

Страница 6: ...amming buttons 9 RSE card connector 10 RIO CONN card connector 11 Connector for plug in radio frequency card AF 12 Earthing star point 13 Terminal board for CRP connection 14 Terminal board for connec...

Страница 7: ...CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions Optional accessories 23 RLB battery charger board 002RLB 24 RGSM001 module...

Страница 8: ...with 60227 IEC 53 IEC For power supplies up to 48 V you can use FROR 20 22 II cables compliant with EN 50267 2 1 CEI To connect the antenna use RG58 cable up to 5 m To connect to the CRP use a UTP CAT...

Страница 9: ...Page 9 Manual FA01554 EN 01 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions INSTALLATION Preparing the control panel...

Страница 10: ...ual FA01554 EN 01 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions Fastening the control panel DIN rail 195 125 Standa...

Страница 11: ...e and without notice Translation of the original instructions ELECTRICAL CONNECTIONS Preparing the electrical cables Connect all wires and cables in compliance with the law Use cable glands to connect...

Страница 12: ...Phase N Neutral Earth The strap used to x the cables is not supplied N F L 2 Power supply output for accessories The output normally delivers 24 V AC The output delivers 24 V DC 10 11 when the batteri...

Страница 13: ...Power W Accessories 10 11 24 AC DC 20 Additional light 10 E3 24 AC DC 10 Flashing beacon 10 E 24 AC DC 10 Operator status warning light 10 5 24 AC DC 3 BUS BUS 15 DC 15 Do not connect anything other t...

Страница 14: ...and without notice Translation of the original instructions Gearmotor with encoder FC1 FA1 F E1 M N E M N E M1 N1 ENC1 EB1 VB R1 M2 N2 ENC2 EB2 VB R2 M1 M2 E2 FC2 FA2 F FC2 FA2 F E2 FROG A24E FERNI FE...

Страница 15: ...tents of this manual may be changed at any time and without notice Translation of the original instructions N M E N M E M1 N1 ENC1 EB1 VB R1 M2 N2 ENC2 EB2 VB R2 M1 M2 STYLO RME N M EB E N M E EB M1 N...

Страница 16: ...me and without notice Translation of the original instructions Gearmotors with slowdown switches FC1 FA1 F FC2 FA2 F M N N M M1 N1 ENC1 EB1 VB R1 M2 N2 ENC2 EB2 VB R2 M1 M2 R R A3024N A5024N FC2 FA2 F...

Страница 17: ...4 EN 01 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions Gearmotors without encoder M N N M M1 N1 ENC1 EB1 VB R1 M2 N2...

Страница 18: ...ch accessory can be con gured on the control panel This method allows you to con gure the set up immediately without having to do so later and intervene directly on the accessories and system wiring C...

Страница 19: ...ng programming 2 Control device NO contact OPEN ONLY function When the HOLD TO RUN function is active the control device must be connected during OPENING 3 Control device NO contact PARTIAL OPENING or...

Страница 20: ...the original instructions Signalling devices 1 Flashing beacon It ashes when the operator opens and closes 2 Additional light It increases the light in the manoeuvring area See Additional light funct...

Страница 21: ...uts If contacts CX and CY are not used they must be deactivated during programming DELTA photocells Standard connection DELTA photocells Connection with safety test See Safety devices test function 10...

Страница 22: ...ranslation of the original instructions DXR DLX photocell Standard connection DXR DLX photocell Connection with safety test See Safety devices test function 10 TS 2 CX CY 10 11 E E3 5 RX TX 10 11 OUT...

Страница 23: ...ay perform this operation Make sure that there are no obstacles in the way Power up the device and begin programming Start programming with the functions indicated below A1 Motor type F46 Number of mo...

Страница 24: ...nvert motion zone in case of obstructions G Stop motion zone in case of obstructions Graph showing speed curves during movement slowdown and approach Moving between the various speeds always involves...

Страница 25: ...Close M1 and CL1 appears on the display When it hits the strike plate press the ENTER button Close M2 and CL2 appears on the display When it hits the strike plate press the ENTER button Open M2 and O...

Страница 26: ...le opening sensitive edges with 8K2 resistor 2r7 Reopen while closing pair of sensitive edges with 8K2 resistor 2r8 Reclose while opening pair of sensitive edges with 8K2 resistor CY input Associate a...

Страница 27: ...ces F6 Hold to run OFF Default ON Command 2 7 Associate a command with the device connected to 2 7 F7 Command 2 7 0 Step by step default 1 Sequential Gate open warning light It signals the gate status...

Страница 28: ...t 2 Courtesy lamp The lighting device remains on for the full duration of the manoeuvre and after the manoeuvre for the time set under the function F25 Courtesy time Automatic closure Set the time bef...

Страница 29: ...closing speed Set the M1 travel speed percentage of maximum speed F28 M1 speed 40 to 100 Default 70 M2 leaf opening and closing speed Set the M2 travel speed percentage of maximum speed F29 M2 speed 4...

Страница 30: ...the percentage of the total travel to be used for M1 opening approach F39 M1 opening approach point 0 5 to 15 0 Default 8 0 M1 closing approach point Set the percentage of the total travel to be used...

Страница 31: ...ly when a memory roll card is inserted into the control board F51 Read data OFF ON Run operation Peripheral number Assign a unique identi cation code CRP address to the control board It is used where...

Страница 32: ...control device to resume movement P7 Reopen while closing P8 Reclose while opening RIO PH T1 Associate one of the available functions with a wireless safety device The function only appears if the RIO...

Страница 33: ...ssign a function to each one The operation can be carried out by using a transmitter or a BUS selector device e g a keypad or transponder reader The board that manages the control devices AF must be i...

Страница 34: ...acquisition procedures are explained in the transmitter manual U8 Self Learning Rolling OFF Default ON Motor type Set the type of gearmotor installed on M1 and M2 A1 Motor type 1 STYLO ME 2 STYLO RME...

Страница 35: ...age Clr will appear FW version Display the rmware version number H1 FW version This shows the version of the board rmware Use the arrows to show the versions of the display board and the control board...

Страница 36: ...and Saving and uploading user and configuration data Save user data and system con guration data on a MEMORY ROLL card The stored data can be reused for another control board of the same type to carry...

Страница 37: ...ervice test failure error E7 Operating time error E9 Consecutive obstacles detected during closing E10 Consecutive obstacles detected during opening E11 Maximum number of obstacles E12 Motor supply vo...

Страница 38: ...Page 38 Manual FA01554 EN 01 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions...

Страница 39: ...Page 39 Manual FA01554 EN 01 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions...