THIS PACKAGE INCLUDES:  

1. DESCRIPTION 

The CX-WEC10BK2 Emergency Control Kit allows an individual to 
push the “PRESS FOR EMERGENCY ASSISTANCE” button to signal 
for help by illuminating the “Assistance Required” annunciator 
on the outside, and the “Assistance Requested” annunciator on 
the inside of the location. At the same time the sounders built 
into both annunciators will activate. The kit includes signage 
that states in the event of an emergency to press the button 
and an audible and visual signal will activate.

The CX-WEC10BK2 kit comes with the inside activation and 
annunciator built onto a double gang combination plate making 
installations quicker since one back box install is needed rather 
that two single gang boxes. The CM-AF142SO offers different 
color options (Red, Green, Blue and White), an adjustable flash 
rate and variable volume control. 

Note: CX-WEC10BK2 Emergency Call System is OBC Regulation 
368/13, Section 3.8.3.12 compliant.

2. OPERATION AT A GLANCE

When the “PRESS FOR EMERGENCY ASSISTANCE” button on 
the CM-AF540SO is pushed in it will change its normally open 
contact to a closed contact and activate the outside light and 
sounder (CM-AF142S0) to signal for help. The inside lights 
and sounder (CM-AF540SO) will also be activated giving the 
individual inside confirmation that the action has taken place. 
Once the emergency has been attended to the red mushroom 
button on the CM-AF540SO can be pulled out to silence and 
reset the system. The flash rate can be adjusted at the top right 
of the circuit board after removing the front dome cover. The 
volume can be increased or decreased by using the adjustment 
screw on the back of the CM-AF142SO. 

Power

Both the CM-AF540SO and the CM-AF142SO can be powered 
with either 12/24 VAC/VDC.

Note: When the CX-WEC10BK2 is integrated with a Camden 
Restroom Control Kit, VDC power must be used to prevent 
the door strike from buzzing.

Wiring the CX-WEC10BK2 Emergency Control Kit 

The inside and outside annunciators are wired in parallel to 
make them work at the same time when triggered.

1- 

CM-AF540SO       

1- 

CM-AF142SO       

1- 

CM-SE21A

Take one of the black wires from the CM-AF540SO and the black 
wire from the CM-AF142SO and tie them to the power supply's 
VDC ground (-). Take the remaining black wire from the 
CM-AF540SO and one of the Red, Blue or Green wires from the 
CM-AF142SO (or take all colored wires from the CM-AF142SO to 
make White) and wire it to the red mushroom buttons, normally 
open contact marked with as terminal “3”. Next, wire the 
terminal marked as “4” to the positive (+) terminal of the 
VDC power supply.

Note: Some Door Operators provide excessive voltage levels 
above their posted values. Always measure voltages provided 
on both the VDC & VAC scales first before applying power to 
any part of the Emergency Control Kit.

3. INSTALLATION

CM-AF540SO 

Supplied with a stainless steel 
faceplate that can be easily 
mounted to a double gang 
electrical box.

Volume Adjust

 

Turn the volume adjust 
clockwise to increase the 
volume and counter 
clockwise to decrease the 
volume. Turn the volume 
adjust all the way counter 
clockwise to turn the 
sounder completely off.

PRESS FOR

EMERGENCY

ASSIST

ANCE

Volume 

Adjust

3

4

1

2