Consideration of the free 
movement of the exit device 
latch and the keeper (jaws)  
of the RIM strike. 

Ensure the latch of the exit 
device and the keeper (jaws) 
of the electric strike have free 
and easy movement to operate 
together, with a minimum of 
friction. In this, a small amount 

of silicone lubricate on both the latch and jaws of the strike 
will improve the operation… but please be careful not to over 
spray. 

Consideration for a 
professionally finished retrofit 
installation. 

Replacing electric strikes used with 
cylindrical or mortise locksets, 
with an exit device and RIM strike, 
will leave holes in the door and 
door frame that must be filled or 
covered. Cover or plug holes and 
check that new cover plates are 

flush with the frame… and will not interfere with the RIM strike. 

Cover plate

flush with 

frame 

Summary

 

Adherence with the recommendations of this guide will avoid the 
most common problems associated with the installation of RIM 
strikes. If you require additional assistance, please contact our 
Technical Support department by phone at 1 877 226-2269 or 
email [email protected].

Содержание CX-ED1259L

Страница 1: ...tion flexibility with field selectable voltage fail safe fail secure operation and mechanical adjustment of the strike body 2 SPECIFICATIONS Voltage 12 24V AC DC Current Draw 280mA 12V DC 140mA 24V DC...

Страница 2: ...he benefit is that once installed Camden s RIM strike will not move out of alignment and require a service call a common occurrence with competitive RIM strikes CX ED1259L is the only thick UL Fire li...

Страница 3: ...4 5 Jamb Hole punch Hole punch Holes for self tapping screws Connecting wire hole 5 8 Connecting wire hole A A B Note 1 Open door slightly and remove the template Note 1 Use a Hole punch on marked po...

Страница 4: ...ne shim The crash bar should only touch this shim not apply pressure when the door is closed 4 While adjusting strike allow a small gap between strike body and crash bar approx 1 8 Mark remaining scre...

Страница 5: ...NOTE The products are intended to be installed in accordance with the installation wiring diagram mechanical assembly drawings provided with each product the local authority having jurisdiction AHJ an...

Страница 6: ...IRES ORANGE GREY WHITE Or 2 4 V 1 2 V Step 4 Setting Fail Secure Fail Safe Product is factory set to fail secure To change from fail secure to fail safe 1 Loosen the screw at the back of the Electric...

Страница 7: ...offer horizontal adjustment to compensate for doors that are misaligned with the door frame but there is a limit to the strike adjustment Check that the door is not binding on the frame An electric st...

Страница 8: ...jaws of the strike will improve the operation but please be careful not to over spray Consideration for a professionally finished retrofit installation Replacing electric strikes used with cylindrica...