CX-ED1259L ‘RIM’ Electric Strike

INSTALLATION INSTRUCTIONS

Page 5 of 8

Spacer (install as needed)

1/4-20 x 1

1

2  screw 

 4pcs

4 -40 x 1

4  Screw 

 4pcs

10-32 x 1  screw

2pcs

4-40 x 

(4pcs)

1/4-20 x 112

1

4

(4pcs)

9

16

''

Horizontal 

Centerline

Jamb

3

8

''

10-32 x 1 

(2pcs)

1''

Jamb

Keeper Shim

Closed Door

Jamb

Top View

Latch

Allow a small gap between 

strike body and crash bar. 

(Approx. 

1

8

'')

Crash Bar

4

6

5

''

''

''

''

''

''

NOTE: The products are intended to be installed in accordance with 
the installation wiring diagram, mechanical assembly drawings 
provided with each product, the local authority having jurisdiction 
(AHJ) and the National Electric Code, NFPA 70. When installed in fail 
secure mode, the local authority shall be consulted with regard to 
the use of possible panic hardware to allow emergency exit from 
the secure area.

The electric door strike shall be installed in such a way and in such 
location so as to not impair the operation of an emergency exit 
device or panic hardware mounted on the door.

Содержание CX-ED1259L

Страница 1: ...tion flexibility with field selectable voltage fail safe fail secure operation and mechanical adjustment of the strike body 2 SPECIFICATIONS Voltage 12 24V AC DC Current Draw 280mA 12V DC 140mA 24V DC...

Страница 2: ...he benefit is that once installed Camden s RIM strike will not move out of alignment and require a service call a common occurrence with competitive RIM strikes CX ED1259L is the only thick UL Fire li...

Страница 3: ...4 5 Jamb Hole punch Hole punch Holes for self tapping screws Connecting wire hole 5 8 Connecting wire hole A A B Note 1 Open door slightly and remove the template Note 1 Use a Hole punch on marked po...

Страница 4: ...ne shim The crash bar should only touch this shim not apply pressure when the door is closed 4 While adjusting strike allow a small gap between strike body and crash bar approx 1 8 Mark remaining scre...

Страница 5: ...NOTE The products are intended to be installed in accordance with the installation wiring diagram mechanical assembly drawings provided with each product the local authority having jurisdiction AHJ an...

Страница 6: ...IRES ORANGE GREY WHITE Or 2 4 V 1 2 V Step 4 Setting Fail Secure Fail Safe Product is factory set to fail secure To change from fail secure to fail safe 1 Loosen the screw at the back of the Electric...

Страница 7: ...offer horizontal adjustment to compensate for doors that are misaligned with the door frame but there is a limit to the strike adjustment Check that the door is not binding on the frame An electric st...

Страница 8: ...jaws of the strike will improve the operation but please be careful not to over spray Consideration for a professionally finished retrofit installation Replacing electric strikes used with cylindrica...

Отзывы: