CAMDEN CV-WRX4 Скачать руководство пользователя страница 1

Page 1 of 2

CV-WRX4

Wiegand Receiver

INSTALLATION INSTRUCTIONS

CV-WRX4 receiver is designed for use with Camden 
CV-WTX2 transmitters. The transmitter signal is codified in two 
different protocols according to its configuration: Wiegand 26 
and Wiegand 37. The receiver provides facility codes 1 to 255 
by DIP switch J9 using 8 bit binary configuration.

2. INSTALLATION AND CONNECTIONS 

Attach the rear part of the enclosure to the wall using the 
plugs and screws supplied. Pass the cables through the 
grommet of the enclosure. Connect the power cables to the 
terminals marked on the mother board, as Indicated. 
Mount the receiver cover and pass the cables and the 
antenna through it. 

3. OPERATING

Configuration and connection for the different protocols. 

Protocol  Power  

Supply 

Signal 

 Outlet

SW1 

Protocol

Format

Wiegand 

26

+ -

D0 and 

D1

Off

8 bits facility code + 16 bits 

credential ID number

Wiegand 

37

+ - 

D0 and 

D1

ON

-

Power Supply

12V DC ( 9VDC - 21VDC)

Frequency  

868.35 MHz

Consumption  

Standby / Operating

14mA / 36mA

Operating 

Temperature

-4°F to +185°F (-20°C to +85°C) 

IP Rating

IP54 (IP65 with cable plug installed)

Dimensions

3 1/4" W x 7 3/8" H x 1 5/8" D 

(82mm x 187mm x 42mm)

1. TECHNICAL CHARACTERISTICS

Note: To use other protocols, contact Camden.
Operations  

The green power on LED will illuminate when power is 
provided. The red signal LED will illuminate for the duration it 
receives the message from the transmitter. 
If the red LED does not illuminate when the transmitter 
button is pressed, the receiver is not receiving the 
transmission signal from the transmitter. Reduce the distance 
to the receiver, and verify the transmitter is working as 
suggested 
Refer to Facility Code DIP switch table to select the value of 
facility code to be sent from the receiver.

+

-

12V dc supply

12V dc supply

CH2

Decoded signal output (D0 Wiegand)
Decoded signal output (D1 Wiegand)

Decoded signal output (D0 Wiegand)
Decoded signal output (D1 Wiegand)

J9

1     2     3     4     5     6     7     8

ON

LSB

MSB

128 64 32

16

8

4

2

1

The DIP switch positions will provide a 

facility code = 34. SW#3 = 32. SW#7 =2. 

The total = 32 + 2 = 34

The DIP switch positions set 

the facility code.
For example:   

34. SW#3 = 32. SW#7 = 2.
The total = 32 + 2 = 34

THIS PACKAGE INCLUDES:  

(1) CV-WRX4 Receiver
(2) #6 x 1-1/4" Screws

(2) #6 Wall Plugs
(1) Cable Plug

CH1

Отзывы: