![CAMDEN CM-9800 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/camden/cm-9800/cm-9800_installation-instructions_3631544001.webp)
Page 1 of 5
CM-9800
Touch Button Switch
INSTALLATION INSTRUCTIONS
Door Activation Devices
SL NO
Component Name
Quantity
1
Wall plug 6mm
3
2
Wall fixing screw 4 x 30mm
3
3
3 x 6 Security Screw
1
4
IN4007 diode
1
5
470nf Capacitor
1
6
10K Res 1/2w
1
7
Security screw driver
1
8
6-32 x 1" Machine screw
2
9
Mounting Template
1
1. GENERAL DESCRIPTION
CM-9800 is a request-to-exit switch, It will work independently
(standalone) or can equally be connected via a controller to
provide exit from a secured area (Push Button Input). With its
slim looks and die-cast metal body, the CM-9800 combines
elegance and aesthetics with ruggedness and reliability.
2. SPECIFICATIONS
Input Voltage
12-24V AC/DC
Current
Consumption
max.65mA
Relay Output
2A at 24V DC / 120V AC
Set Relay Time
0.5 to 60 seconds or Toggle (ON/OFF)
Indicators-LED
Orange, red, green
LED Control
Yes, by DIP switch
Tamper
Yes
Backlight ON/OFF
Yes, by DIP switch
Buzzer ON/OFF
Yes, by DIP switch
Operating
Temperature
-4°F to 122°F (-20°C to 50°C)
Operating Humidity
Non-condensing up to 95%
Housing
Die-cast Aluminium alloy
Touch Plate
Mild Steel Painted
Protection
IP66
Dimension
3.34” W x 4.5” L x 1/32” H
(85 mm x 116.6 mm x 22.6 mm)
3. MOUNTING
1. Identify a suitable location on wall or flat surface.
2. Stick the Drilling Template provided on chosen location.
Drill 3 holes as indicated in the diagram.
3. Insert 3 nos. of 5 mm wall plugs provided into the drilled holes.
4. Route the cables through the holes provided in the
BackPlate.
5. Fix the Backplate firmly on the wall using 3nos. of 3 x 30mm
CSK screws
6. Connect wires.
7. After wiring, place the Housing over the fixed backplate and
guide the slot into the backplate tab and slide it downwards.
8. Fix the Housing to the Back-Plate with a M3 x 6 mm Security
Screw on the bottom of the Housing using a Security
Screwdriver provided.
Important Note: Several layers of protection are provided
against transient voltages from static discharge, lightning
and power supply spikes. For protection to be fully effective,
earth grounding should be done correctly.
12/24 V
AC/DC
NC
COM
LR-
LG-
Tamp
Tamp
Tamper Switch
Tamper Switch
12 to 24VDC
12 to 24VAC
Red LED light
Green LED light
Normally closed
Common
NO
LED com
(GND)
Normally open
LED common
Grey
Color
Blue
Black &
Red
Orange
Yellow
Pink
White
Purple
Green
Red
Black
Green
Orange
Yellow
Pink
White
Purple
Grey
Blue
12/24V
AC/DC
LED com (GND)
LR -
LG -
NC
COM
NO
Tamp
Tamp Tamper
Relay 2A
Power Supply