![Cambium PTP 670 Series Скачать руководство пользователя страница 359](http://html.mh-extra.com/html/cambium/ptp-670-series/ptp-670-series_user-manual_485665359.webp)
Chapter 5: Installation
Supplemental installation information
Page 5-62
Replacing PSU fuses
The AC+DC Enhanced Power Injector 56V contains two replaceable fuses. These fuses protect
the positive and negative grounded DC input voltages. If an incorrect power supply (that is, not
in the range 37V to 60V DC) is connected to the DC input terminals, one or both fuses may
blow.
Both fuses are 3 Amp slow-blow, for example Littlefuse part number 0229003.
To replace these fuses, undo the retaining screw and hinge back the cover as indicated:
Note
No other fuses are replaceable in the AC+DC Enhanced Power Injector 56V.
Note
The AC Power Injector 56V does not contain replaceable fuses.
Содержание PTP 670 Series
Страница 1: ...F Cambium PTP 670 Series User Guide System Release 670 02 50 ...
Страница 349: ...Chapter 5 Installation Installing an SFP Ethernet interface Page 5 52 Correct Incorrect ...
Страница 405: ...Chapter 6 Configuration and alignment System menu Page 6 46 Figure 151 LAN Configuration page PTP topology TDM support ...
Страница 406: ...Chapter 6 Configuration and alignment System menu Page 6 47 Figure 152 LAN Configuration page PTP topology SFP support ...
Страница 408: ...Chapter 6 Configuration and alignment System menu Page 6 49 Figure 154 LAN Configuration page HCMP topology ...
Страница 416: ...Chapter 6 Configuration and alignment System menu Page 6 57 Figure 156 QoS Configuration page IP MPLS ...
Страница 445: ...Chapter 6 Configuration and alignment Management menu Page 6 86 Figure 173 Time Configuration page SNTP enabled ...
Страница 551: ...Chapter 7 Operation System statistics Page 7 64 Figure 250 Main Port Counters page when main port is bridging traffic ...