![Cambium PTP 450 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/cambium/ptp-450/ptp-450_configuration-and-users-manual_3577514084.webp)
Task 4: Configuring General and Unit settings
PTP 450 Configuration and User
pmp-0815 (August 2015)
3-27
Unit settings tab of BHS
Figure 18
Unit Settings tab of BHS
The
Unit Settings
tab of the BHS contains an option on how a BHS must react when it
detects a connected override plug.
This tab has also option to import and export of BHS configuration via config file. The
import and export procedure is described in
Import and Export of config file
on page
Table 17
BHS Unit Settings attributes
Attribute
Meaning
Set to Factory
Defaults Upon
Default Plug
Detection
If
Enabled
is checked, then an override/default plug functions as
a default plug. When the module is rebooted with the plug
inserted, it can be accessed at the IP address 169.254.1.1 and no
password, and all parameter values are reset to defaults.
A subscriber, technician, or other person who gains physical
access to the module and uses an override/default plug
cannot see
or learn the settings that were previously configured in it. When
the module is later rebooted with no plug inserted, the module
uses the new values for any parameters that were changed and
the default values for any that were not.