Chapter 19: Alarm Management and Troubleshooting (CLI)
Configuring Voltage Alarm Thresholds and Displaying Voltage
PMs (CLI)
phn-3963_008v000
Page 19-7
Configuring Voltage Alarm Thresholds and
Displaying Voltage PMs (CLI)
You can configure undervoltage and overvoltage alarm thresholds.
The default thresholds for PTP 850E are:
•
Undervoltage Raise Threshold: 36V
•
Undervoltage Clear Threshold: 38V
•
Overvoltage Raise Threshold: 60V
•
Overvoltage Clear Threshold: 58V
These thresholds determine when the following alarms are raised and cleared:
•
Alarm #32000: Under voltage
•
Alarm #32001: Over voltage
To display the current thresholds, enter the following command in root view.
root> platform management voltage thresholds show
To change the threshold for raising an undervoltage alarm, enter the following command in root view:
root> platform management undervoltage set raise-threshold <0-100>
To change the threshold for clearing an undervoltage alarm, enter the following command in root view:
root> platform management undervoltage set clear-threshold <0-100>
To change the threshold for raising an overvoltage alarm, enter the following command in root view:
root> platform management overvoltage set raise-threshold <0-100>
To change the threshold for clearing an overvoltage alarm, enter the following command in root view:
root> platform management overvoltage set clear-threshold <0-100>
You can display voltage PMs that indicate, per 15-minute and 24-hour periods:
•
The number of seconds the unit was in an undervoltage state during the measured period.
•
The number of seconds the unit was in an overvoltage state during the measured period.
•
The lowest voltage during the measured period.
•
The highest voltage during the measured period.
To display voltage PMs, enter the following command in root view:
root> platform management voltage pm show pm-interval-type
<all|15min|24hr>