Chapter 7: Quality of Service (QoS)
Configuring Policers (Rate Metering)
phn-3963_008v000
Page 7-17
2.
Select the interface in the Ethernet Logical Port Configuration Table and click
Policers
. The Policers page
opens. By default, the Policers page opens to the Unicast Policer table (
3.
In the
Policer profile
field, select a profile from the policer profiles defined in the system. The
Policer profile
drop-down list includes the ID and description of all defined profiles.
4.
In the
Unicast admin
field, select
Enable
to enable policing on unicast traffic flows from the logical interface,
or
Disable
to disable policing on unicast traffic flows from the logical interface.
5.
Click
Apply
.
Assigning Multicast Policers
To assign a policer for multicast traffic to a logical interface:
1.
Select Ethernet > Interfaces > Logical Interfaces. The Logical Interfaces page opens (
2.
Select the interface in the Ethernet Logical Port Configuration table and click Policers. The Policers page opens.
By default, the Policers page opens to the Unicast Policer table (
3.
Select Multicast Policer. The Multicast Policer table appears.
Figure 107
Logical Interfaces – Policers Page – Multicast Policer
4.
In the Policer profile field, select a profile from the policer profiles defined in the system. The Policer profile
drop-down list includes the ID and description of all defined profiles.
5.
In the Multicast admin field, select Enable to enable policing on multicast traffic flows from the logical
interface, or Disable to disable policing on multicast traffic flows from the logical interface.
6.
Click Apply.