Chapter 7: PTP 820S Detailed Configurations Description
1+1HSB/2+0 Single Polarization Direct Mount
phn-3972 004v000
Page 7-14
1+1HSB/2+0 Single Polarization Direct Mount
Figure 19 1+1HSB/2+0 Single Polarization Direct Mount
HSB
ACCP
Note
This procedure can also be used for 1+0SP HW ready for 2+0 SP configuration.
List of Items
Table 26 Required items for 1+1HSB/2+0 Single Polarization Direct Mount configuration
Item
Description
Quantity
Remarks
1
PTP 820S Radio
2
2
RFU-C Coupler/Splitter KIT
1
For 1+1HSB
configuration, a coupler
must be used
3
RFU-C Twist KIT
1
Required Tools
The following tools are required for the installation:
•
Metric offset hexagon key wrench #6
•
Phillips #2 screwdriver
•
Metric offset hexagon key wrench #2.5 and #3
Procedure
In 1+1 direct mount installation, the PTP 820S is attached to a coupler. To install a PTP 820S in a
direct mount 1+1 configuration: