Chapter 3: Cable Installation and Grounding
Cable Grounding
phn-3962 004v000
Page 3-3
Cable Grounding
Cables must be grounded as follows:
•
For Fiber cables
Connecting an Optical Fiber Cable and SFP
, no grounding is
required.
•
For DC power cables
see connecting a DC power cable on page 3-25
)
, no grounding is
required.
•
For Ethernet cables
), the shielded Ethernet
cable (SF/UTP construction must be grounded to the antenna tower at the top (next to the PTP
820 unit). The entry to the indoor cabinet and every 50m, using the kit N000082L017A.
Figure 9 Grounding cable
Table 10 Cable Grounding Kit
Part Number
Description
N000082L017A
PTP 820 Grounding Kit for CAT5e F/UTP 8mm cable