Chapter 24: Alarm Management and Troubleshooting (CLI)
Performing Diagnostics (CLI)
phn-3965_006v002
Page 24-17
•
CCM (Continuity Check Message)
–
MEPs in the network exchange CCMs with their peers at defined intervals.
This enables each MEP to detect loss of connectivity or failure in the remote MEP.
Configuring MDs (CLI)
In the current release, you can define one MD, with an
MD Format
of
None
.
To add an MD, enter the following command in root view:
root> ethernet soam md create md-id <md-id> md-format none md-name <md-
name> md-level <md-level>
Note
Support for MDs with the MD format Character String is planned for future release. In this release,
the software enables you to configure such MDs, but they have no functionality.
The following command creates MD 5, named TR-988 with maintenance level 5.
root> ethernet soam md create md-id 5 md-format none md-name TR-988 md-
level 5
To delete an MD, enter the following command in root view. Before deleting an MD, you must delete any MA/MEG
associated with the MD.
root> ethernet soam md delete md-id <md-id>
To display a list of MDs and their attributes, enter the following command in root view:
root> ethernet soam md show
Table 324
Maintenance Domain CLI Parameters
Parameter
Input Type
Permitted Values
Description
md-id
Number
1-4294967295
md-name
String
Up to 43 alphanumeric
characters.
An identifier for the MD. The MD Name should
be unique over the domain.
md-level
Number
0-7
The maintenance level of the MD. The
maintenance level ensures that the CFM frames
for each domain do not interfere with each
other. Where domains are nested, the
encompassing domain must have a higher level
than the domain it encloses. The maintenance
level is carried in all CFM frames that relate to
that domain. The maintenance level must be the
same on both sides of the link.
Note:
In the current release, the maintenance
level is not relevant to the SOAM functionality.
Содержание PTP 820 Series
Страница 1: ...User Guide ...
Страница 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Страница 57: ...Chapter 1 Introduction Front Panel Description phn 3965_006v002 Page 1 11 Figure 5 SM Card and Cover ...
Страница 114: ...Chapter 2 Getting Started Changing the Management IP Address phn 3965_006v002 Page 2 19 10 Click Apply ...
Страница 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Страница 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Страница 357: ...Chapter 5 Radio Configuration Configuring and Viewing Radio PMs and Statistics phn 3965_006v002 Page 5 43 ...
Страница 371: ...Chapter 5 Radio Configuration Configuring and Viewing Radio PMs and Statistics phn 3965_006v002 Page 5 57 ...
Страница 678: ...Chapter 12 Alarm Management and Troubleshooting Performing Diagnostics phn 3965_006v002 Page 12 28 ...
Страница 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Страница 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...
Страница 809: ...Chapter 17 Radio Configuration CLI Configuring and Viewing Radio PMs and Statistics CLI phn 3965_006v002 Page 17 20 ...
Страница 867: ...Chapter 18 Ethernet Services and Interfaces CLI Viewing Ethernet PMs and Statistics CLI phn 3965_006v002 Page 18 48 ...
Страница 1002: ...Chapter 22 Synchronization CLI Configuring 1588 Transparent Clock CLI phn 3965_006v002 Page 22 15 ...
Страница 1149: ...phn 3965_006v002 Page V Term Definition WRED Weighted Random Early Detection XPIC Cross Polarization Interference Cancellation ...