Installation Guide for RFU-D-HP
Page 53 of 179
Connecting a DC Power Cable
A DC power cable must be connected to port P1 to provide power from an external power source to the RFU.
To connect a DC power cable:
1 Strip off 45 mm from the cable jacket.
2 Expose 10 mm at the edge of each of the two wires.
3 Insert the power cable into the gland.
4 Insert the power cable wires into the power connector.