PTP 800 Series User Guide
Managing perform ance
phn- 2513_004v000 ( Oct 2012)
7- 63
Figu r e 1 9 6
Diagnost ics page ( 1+ 1 link)
Using the diagnostics plotter
The diagnostics plotter can trace the following statistics (refer to
definitions):
•
Vector Error
•
Rx Power
•
Tx Power
•
Link Loss
•
Rx Data Rate
•
Tx Data Rate
•
Aggregate Data Rate
•
Protection State: In a 1+1 Hot Standby configuration, only one CMU / RFU at a given
end of the link is Active at any one time, the neighbor CMU / RFU being Inactive. The
Protection State indicates whether a CMU / RFU is in the Active or Inactive state.
•
Remote Primary Secondary Mode: This indicates the Primary /Secondary Mode of the
active unit at the remote end of the wireless link.