PMP Synchronization Solutions User Guide
Installing the CMM5
PMP-0297 007v001 (January, 2017)
2-49
Class A Emissions Requirements
The following are the major requirements for the CMM5 to meet Class A Emission
requirements when fully loaded with access points.
•
240W and 600W AC Power supplies: It is recommended to us a DC line filter as described
above.
•
CMM5 56V Injectors: In some cases it may be necessary to install Ferrite beads on the input
and output CAT5 Ethernet cables. Refer to the installation photos above for the
recommended locations of these beads. Recommended device is a large snap on bead
with inside dia. 6.3mm, to be used on all 8 pin RJ45 and 6 pin RJ25 within three inches of
the CMM5.