Chapter 2: System hardware
Cabling
Page
2-37
Cabling
Ethernet standards and cable lengths
All configurations require a copper Ethernet connection from the ODU (Main PSU port) to the Power
supply.
Table 42 PSU drop cable length restrictions
System configuration
Maximum cable length (m/ft)
Power supply
PoE powered device
on AUX/SYNC port
From power supply
to ODU
From ODU to PoE
device on AUX/SYNC
port
Power supply (30W)
None
100 m
N/A
IEEE 802.3at Type 2 Not supported
AC Power Injector (60W)
None
100 m
N/A
IEEE 802.3at Type 2 100 m in total
AC+DC enhanced Power
Injector
None
100 m
N/A
IEEE 802.3at Type 2 100 m in total
-48 V DC power injector
None
100 m
N/A
IEEE 802.3at Type 2 100 m in total
CMM4 with 56 V supply
None
100 m
N/A
IEEE 802.3at Type 2 Not supported
IEEE802.3at compliant
supply
None
100 m
N/A
IEEE 802.3at Type 2 Not supported
Note
The Ethernet connectivity for CMM4 requires the part “Ethernet cable adapter for CMM4 –
N000045L001A”.