Chapter 5: Installation
Installing external antennas to a connectorized
ODU
Page
29
4
Attach the plate mounted AP to the antenna and tighten the (4) serrated flange nuts using a
spanner wrench
Figure 87 Attaching the plate
5
Connect the port A of AP to vertical and port B of AP to horizontal polarization interfaces of
the antenna with RF cable. Tighten the N type connectors to a torque setting of 1.7 Nm (1.3 lb
ft).
Figure 88 Connect the port A and B to the PMP 450i AP