Chapter 3: System planning
Remote AP Deployment
Page
3-63
Wiring to Extend Network Sync
The following procedure can be used to extend network sync by one additional hop, as described under
Passing Sync in an Additional Hop
. When a co-located module receives sync over the air,
the co-located modules can be wired to pass the sync as follows:
1.
Connect the GPS Utility ports of the co-located modules using a sync cable with RJ-11 (for 450)
or RJ-45 (for 450i/450m) connectors.
2.
Set the Sync Input parameter on the Configuration page of the co-located AP or BH timing
master to AutoSync.
3.
Set the Device Type parameter on the Configuration page of the co-located AP or BH timing
master to Remote.
4.
Set the Sync Output to Aux Port parameter on the Configuration page of the co-located AP or
BH timing master to Disabled.
5.
Set the UGPS Power parameter on the Configuration page of the co-located AP or BH timing
master to Disabled.
6.
Set the Frame Timing Pulse Gated parameter on the Configuration page of the co-located SM or
BH timing slave to Enable.
Note
This setting prevents interference if the SM or BH timing slave loses sync.
Figure 69 Co-located AP or BH timing master Sync Setting configuration
Содержание PMP 450 AP
Страница 79: ...Chapter 2 System hardware System Components Page 2 29 Figure 20 Gigabit Enet Capable power supply...
Страница 160: ...Chapter 3 System planning Radio Frequency planning Page 3 30 Figure 55 Sector Antenna...
Страница 161: ...Chapter 3 System planning Radio Frequency planning Page 3 31 Figure 56 cnMedusa Antenna...
Страница 189: ...Chapter 3 System planning Remote AP Deployment Page 3 59 Figure 65 Remote AP wired to SM that serves as a relay...