Cam Spray

520 Brooks Road

Iowa Falls, IA  50126

toll free: 1.800.648.6007

direct: 1.641.648.5011

fax: 1.641.648.5013

e-mail: [email protected]

Cam Spray 

Hot Water Models

Electric-powered, diesel-fired hot water power washers

M

Mooddeell

1450SHDE
1000SHDE
1000QE
1500SHDE
1500QE
20005SHDE
2000SHDE
2000QE
3000SHDE
3000QE
2000TRDE
3000TRDE
4000QE

H

Hoorrsseeppoow

weerr

2.0 Elec
2.0 Elec
2.0 Elec
3.0 Elec
3.0 Elec
5.0 elec
5.0 Elec
5.0 Elec
7.5 Elec
7.5 Elec
5.0 Elec
7.5 Elec
10.0 Elec

FFuueell ttyyppee

For all:

No. 1

diesel,

No. 2

diesel,

or

kerosene

W

Weeiigghhtt ((llbbss))

350
350
350
350
350
360
570
525
600
550
670
600
575

VVoollttss//AAm

mppss

120/20
120/20
120/20
220/20
220/20
220/20
220/25
220/25
220/34
220/34
220/25
220/34
220/41

G

GPPM

M

2.0
3.0
3.0
3.0
3.0
3.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0

PPS

SII

1450
1000
1000
1500
1500
2000
2000
2000
3000
3000
2000
3000
4000

1

OPERA

TORS MANU

AL

Images, from left, illustrate SH, QE & 1450SH-style pressure washers.

Содержание 1000QE

Страница 1: ...c 2 0 Elec 3 0 Elec 3 0 Elec 5 0 elec 5 0 Elec 5 0 Elec 7 5 Elec 7 5 Elec 5 0 Elec 7 5 Elec 10 0 Elec F Fu ue el l t ty yp pe e For all No 1 diesel No 2 diesel or kerosene W We ei ig gh ht t l lb bs s...

Страница 2: ...on proper installation start up use and storage of your pressure washer Your new pressure washer was tested after production for proper pressure and flow Please note that this process will sometimes...

Страница 3: ...urer s warranty obligation is limited to repair and replacement of defective products as provid ed herein and the Manufacturer shall not be liable for any further loss damages or expenses including da...

Страница 4: ...only in well ventilated areas or vent the exhaust to the outside High pressure water can cause death or serious injury Warning high temperature water Wear protective clothing and face shield Do not d...

Страница 5: ...on pressure washers that filter the water they can only filter poor quality water for a short period of time before they clog Clogging would result in damage to the machine Therefore you should insur...

Страница 6: ...handle see wand breakdown page 10 on the wand is turned counter clock wise This enables the pressure to drop to approximately 250 PSI and draw chemical this is a valve that allows the water to flow th...

Страница 7: ...o ol ld d U Un nl lo oa ad de er r d do oe es s n no ot t b by yp pa as ss s U Un nl lo oa ad de er r c cy yc cl le es s w wh he en n g gu un n i is s s sh hu ut t o of ff f W Wa at te er r i in n c c...

Страница 8: ...no 2 diesel Replace fuel filter Pull trigger gun water flow must go through coil to operate heater Turn thermostat dial to the on position Troubleshooting common problems and solutions cont For proble...

Страница 9: ...male into black female 4 Connect power supply 5 Start machine using normal procedure Does burner fire Replace thermostat While machine is running disconnect fuel line at burner housing Is fuel flowin...

Страница 10: ...20005 MD4 0 20U 2000 3000 Tank f fuel 540172 Cap f fuel 524374 Wheel 524518 Cap w wheel 509570 Switch m motor 93507000 Pump Motor GEN 190399 Wheel 524518 Cap W Wheel 509570 Switch b burner 526300 Hose...

Страница 11: ...el 540178 Unloader a assly UB 22 2000 3000 YU2140 4000 Hose j jumper pump coil 509094 30 Injector c chemical 509555 Coupler f fitting 527715 M x F 1000 4 4000 Q QE Injector c chemical 509555 Coupler f...

Страница 12: ...B3616 B51843U Description Fuel pump with valve Valve coil Valve stem Electrode set Transformer Motor Coupler Blower wheel Gasket Strainer kit 230 Volt AC Part No B21844U B21756U B21877U B5780 540138 1...

Страница 13: ...3 8 100 x 3 8 1450SHDE 00035 Q Meg 15035 Q Meg 25035 Q Meg 40035 Q Meg 1000 20005 and 3000 SH QE and TR 0004 Q Meg 1504 Q Meg 2504 Q Meg 4004 Q Meg Forward g grip soap c control v valve Activates che...

Отзывы: