AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 288 of 402
8.9.11
System Firmware Commands
Query Format
SYSTem:FW:POWER[:VERsion]?
Description
This command returns the firmware revision of the power converter
DSP’s. This information is for reference only.
Returned Data Format
<cr>-<cr>
Query Example
SYST:FW:POWER:VER?
81.0.0.RC8-77.1.0
Query Format
SYSTem:FW:FRONTPANEL:VERsion?
Description
This command returns the firmware revision of front panel controller
processor. This information is for reference only.
Returned Data Format
<cr>
Query Example
SYST:FW:FRONTPANEL:VER?
2.0.0
Query Format
SYSTem:FW:FRONTPANEL:APPS:VERsion?
Description
This command returns the firmware revision of front panel controller
user interface application. This information is for reference only.
Note: This revision number is also returned as part of the *IDN?
query response.
Returned Data Format
<cr>
Query Example
SYST:FW:FRONTPANEL:APPS:VER?
2.0.0
Query Format
SYSTem:HWREVision?
Description
This command returns the hardware revision (build) of the power
source.
Returned Data Format
<nr2>
Query Example
SYST:HWREV?
0