2013 Portable Spa
LTR20131000, Rev. E
Operating
Your Spa
www.calspas.com
22
BP2000 Control Operation
As soon as the Priming Mode screeen appears on the
panel, press the
Jets 1
button once to start Pump 1
in low speed and then again to switch to high speed.
Also, select the other pumps, to turn them on. The
pumps should be running in high speed to facilitate
priming.
If the pumps have not primed after two minutes,
and water is not flowing from the jets in the spa,
do not allow the pumps to continue to run. Turn off
the pumps and repeat the process. Note: Turning the
power off and back on again will initiate a new pump
priming session.
Sometimes momentarily turning the pump off and on
will help it to prime. Do not do this more than five
times. If the pumps will not prime, shut off the power
to the spa and call for service.
Important: A pump should not be allowed to run
without priming for more than two minutes. Under
NO circumstances should a pump be allowed to run
without priming beyond the end of the 4 to 5 minute
priming mode. Doing so may cause damage to the
pump and cause the system to energize the heater
and go into an overheat condition.
After the initial start-up sequence, the control will
enter Priming Mode, which lasts 4 to 5 minutes. The
Priming Mode screen will appear, which will only show
pump icons. The system will automatically return to
normal heating and filtering at the end of the priming
mode.
During the priming mode, the heater is disabled to
allow the priming process to be completed without the
possibility of energizing the heater under low-flow or
no-flow conditions. Nothing comes on automatically,
but the pump(s) can be energized by selecting the
“Jet” buttons. If the spa has a Circ Pump, it can
be turned on and off by pressing the “Circ Pump”
button during Priming Mode. In addition, if the spa
has a Circ Pump, it can be activated by pressing the
dedicated “Light” button during Priming Mode.
Manually exit Priming Mode by pressing the “Exit”
Button.
You can manually exit Priming Mode by pressing an
Up or Down button. Note that if you do not manually
exit the priming mode as described above, the
priming mode will be automatically terminated after
4 to 5 minutes. Be sure that the pumps have been
primed by this time.
Once the system has exited Priming Mode, the top-side
panel will momentarily display the set temperature
but the display will not show the temperature yet.
This is because the system requires approximately
one minute of water flowing through the heater to
determine the water temperature and display it.
Priming Mode
Priming the Pump
Exiting Priming Mode