CS3000 User’s Guide
64
Calsense
Note:
This menu item only displays if there is a flow meter in use and Flow Checking is enabled for leak
detection.
To select alert actions (Figure 53):
1.
From Main Menu, navigate to
Mainlines
and select
Alert Actions
. The Alert Actions screen
displays.
2.
Navigate to the desired Station Group.
3.
For both High and Low Flow Action, use
+/-
to select the desired action:
•
No Alerts
: The controller will take no action and not notify you. This is not
recommended.
•
Alert/No Action
: An alert is generated when the high or low flow occurs, but not
additional action is taken. This is commonly used when low flows are detected.
•
Alert/Shutoff
: An alert is generated and the valve is shutoff. This is commonly used
when high flows are detected.
Maximum Time to Fill Mainline
Provides the ability to set the length of time required to fill the mainline or lateral after a valve opens to
stabilize the flow readings.
To increase or decrease the line fill time (Figure 54):
1.
From Main Menu, navigate to
POCs
menu and select
Line Fill Times
.
2.
Navigate to desired Station Group and use the
+/-
to increase or decrease the line fill time.
3.
When finished, press
BACK
to save changes, and return to Main Menu.
Figure 54: Line Fill Times Screen