To schedule the controller to acquire expected flow rates for one or more Station Groups (Figure 49):
1.
From Main Menu, navigate to
POCs
and select
Acquire Flow Rates
. The Acquire Flow Rates
screen displays.
2.
For each Station Group, use
+/-
to select whether to acquire the expected flow rate the next
time it irrigates or not.
Note:
Setting this to yes may extend your water window for the subsequent irrigation.
Delay Between Valves
The Delay Between Valve Times feature provides the ability to stop the next valve from turning on after
a particular valve closes. This is commonly used when a Station Group has slow closing valves to ensure
there is enough pressure behind a valve to open it.
Caution:
This setting may substantially extend the watering window. If your system has slow closing
valves, Calsense recommends isolating these valves to their own Station Group and only setting this for
that group.
Figure 49: Acquire Flow Rates Screen
Figure 50: Delay Between Valve Times Screen