CS3000 User’s Guide
26
Calsense
2.
Navigate to desired station and use
+/-
to turn on or off a station.
3.
When finished, press
BACK
to save changes, and return to Main Menu.
Stations On-at-a-Time
The On-at-a-Time feature provides the ability to set up the number of valves that come on
simultaneously within a Station Group and within a Mainline. This ensures that the water pressure
within a group and mainline stays consistent. If too many valves are on at a time, the water pressure loss
will result in poor coverage.
To set on-at-a-time (Figure 15):
1.
From Main Menu, navigate to
Mainlines
and select
On-at-a-Time
.
2.
Navigate to the desired Station Group.
3.
Navigate to On-at-a-Time Within Group column and use
+/-
to adjust number of valves that can
irrigate simultaneously within the same Station Group.
4.
Navigate to On-at-a-Time Within Mainline column and use
+/-
to adjust number of valves that
an irrigate simultaneously within the same Mainline.
5.
When finished, press
BACK
to save changes, and return to the main menu.
Figure 15: On-at-a-Time Screen