Digital Broadcast IP Production Console
Surface Ethernet Switches
The surface Ethernet switches are the
interfaces between the control surface via
the section processors and the Impulse
processing cores. To provide redundancy,
two surface Ethernet switches are fitted,
primary and secondary.
The system will always attempt to
boot and run on the primary, however
if there is a problem with the primary
or its connections, the secondary will
automatically take over.
Like the section processors, the primary
and secondary surface Ethernet switches
are housed in a ventilated enclosure
under the upper surface at the rear of
the console in any two of the console
sections.
In Fig 1 below they are shown in section 1
and section 3, when viewed from the rear,
the primary surface Ethernet switch is
usually placed in the left hand section.
The communication with all the control
panels and displays is via each section
processor. Each section processor is
connected to the primary and secondary
surface Ethernet switches using the
primary and secondary GB Ethernet ports
on each section processor.
The primary surface Ethernet switch
typically has 10 ports and each of
the sections connect to a port. In
the example below ports 1-3 are
connected leaving ports 4-8 available for
connections to sections 4-8 depending
on the size of the surface.
Port 9 is used as the IP link from the
primary surface Ethernet switch to the
primary Impulse core on SFP Port 3 of
the control processor module.
See the blue connections in Fig 1.
This is repeated using the section
processor's secondary ports to the
secondary surface Ethernet switch and
on to the secondary Impulse Core on SFP
Port 3 of the control processor module.
See the red connections in Fig 1.
Note: the 2 Impulse cores are directly
connected between both control
processor modules on SFP port 5’s, for
IP network redundancy.
See the yellow connection in Fig 1.
Note: if there is a requirement to add
other console sections to this surface
in the form of a Sidecar where say a
separate console on wheels is brought
into the studio, then the connections
from the Ethernet switches in the sidecar
or if no switches the connections directly
from the section processors can be
added to the Primary and Secondary
Ethernet switches rather than routing
the cables back to the Impulse cores
separately. The sidecar may not even be
in the same room as due to the nature of
the IP Network the physical location of
the surfaces are not a factor.
FIG 1 - SURFACE SECTION CONNECTIONS TO IMPULSE CORES VIA BUILT IN ETHERNET SWITCHES
SURFACE TO CORE CONNECTIONS
Содержание ARGO
Страница 1: ...calrec com ARGO INSTALLATION TECHNICAL MANUAL Digital Broadcast IP Production Console...
Страница 5: ...calrec com ARGO INFORMATION...
Страница 9: ...calrec com ARGO CONTROL SURFACES...
Страница 15: ...15 FIG 7 FLOOR STAND FITTED CASTORS END ELEVATION ARGO Q...
Страница 25: ...calrec com ARGO IMPULSE PROCESSING CORE...
Страница 32: ...32 ARGO Digital Broadcast IP Production Console...
Страница 33: ...calrec com ARGO CONNECTION INFORMATION...
Страница 54: ...54 ARGO Digital Broadcast IP Production Console...
Страница 55: ...calrec com ARGO EXTERNAL CONTROL...
Страница 58: ...58 ARGO Digital Broadcast IP Production Console External Control...
Страница 59: ...calrec com ARGO CONFIGURATION SETUP...
Страница 66: ...66 ARGO Digital Broadcast IP Production Console...
Страница 67: ...calrec com ARGO PANEL OPTIONS...
Страница 74: ...74 ARGO Digital Broadcast IP Production Console...
Страница 75: ...calrec com ARGO SPECIFICATIONS...
Страница 91: ...91 USER NOTES...