CCI Thermal Technologies Inc.  2767 Brighton Road, Oakville, ON L6H 6J4  Tel. (905) 829-4422  Fax (905) 829-4430

www.ccithermal.com

MI243 REV. 3

2.4

If the heater is used on a horizontal drum the liquid

must be of low viscosity and, as with vertical drums, must
be non-volatile.

2.4.1

To ensure that the terminals do not overheat,

position the heater so that the terminal box remains on
the side of the drum, not at the top or bottom.

Note: Painted drums may show signs of singeing at the
point of heater contact.

3.0 START UP AND OPERATION

3.1

 After clamping to the vessel, plug in the heater. Do

not allow the power cord to come in contact with the heater
surface.

3.2

Adjust the thermostat to the desired setting. The

adjustable surface temperature sensing thermostat has
a 120° to 180°F (50° to 82°C) range. This control is not
intended for close temperature regulation.

4.0 MAINTENANCE

The DHF drum heater is constructed to operate in tough
industrial applications with a minimum of maintenance.
However some routine maintenance is recommended
to extend the life of the heater and its components.

ALWAYS UNPLUG THE HEATER BEFORE PERFORMING
ANY MAINTENANCE.

4.1

Keep the heater element assembly clean for

improved heat transfer.

4.2

Open the terminal enclosure to inspect for

cleanliness and dampness. Check all electrical
connections and tighten if necessary. Under normal
operating conditions yearly maintenance should be
sufficient.

5.0 REPLACEMENT PARTS

  Description

Part No.

  Thermostat

AW702S

  Power Cable c/w Plug

12/3 50W 90° Cable x 8 Ft.
(For 120V Models)
c/w 5 - 20P Plug

14/3 50W 90° Cable x 8 Ft.
(For 240V Models)
c/w 6 - 20P Plug

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

FOR DHF DRUM HEATERS

The DHF drum heater is designed specifically for heating
the contents of a standard 45 gallon (55 U.S. gallon)
drum having a 22 1/2" (572mm) diameter. The heater is
intended primarily for use on vertically positioned drums
containing low or medium viscosity liquids.

Despite its versatility caution must be employed in its
use in that the DHF heater may have an operating surface
temperature of up to 600°F (315°C). For this reason we
suggest an insulation cover be placed over the heater to
protect personnel and to improve efficiency.

(Note: Insulation must not cover the terminal box).

The DHF drum heater is NOT suitable:

i)

for heating highly volatile liquids

ii)

for heating closed containers

iii)

for operation in hazardous environments

1.0 INITIAL INSPECTION

1.1

Upon receipt from the carrier, inspect the heater for

possible damage in transit. If necessary, immediately
report damage to the shipping company.

1.2

Verify that the nameplate voltage, wattage and

catalog number comply with the order.
Do not connect the DHF drum heater to an electrical supply
voltage other than that shown on the product nameplate.

2.0 INSTALLATION

2.1

Install the heater around the bottom section of the

drum to improve heat transfer.

2.2

The springs are intended to tighten the heater over

the drum while taking up any slack due to thermal
expansion. Adjust tension by tightening the hex nuts
located on the clamping bracket.

2.3

The electrical receptacle must match the plug

configuration (see below).

Type 5-20R

(120 V)

Type 6-20R

(240 V)