Door alarm
Alarm output
When the alarm occurs, the following message displays:
TID-000 01-09-10 17-15-00
* 001 REPT ALM ENV
"N2-1:MN,OPENDR,NSA,9-10,17-15-00,NEND;"
Clearing output
You will see this message once the alarm has been cleared from the system.
TID-000 01-09-10 17-15-00
A 001 REPT EVT ENV
"N2-1:OPENDR,CL,9-10,17-15-00;"
Description
Severity
The door (OPENDR) alarm indicates one of the five cabinet doors is
open.
To disable the door alarm while maintenance personnel are accessing the
outdoor cabinet the door alarm switch should be pulled out while the
door is open.
Minor