2.1.7 Unit Protection
Input Over current:
In-line fast acting fuses. Check fuse rating in Service and Maintenance
section. Ratings will depend on AC input configuration settings.
Circuit breaker for LV supply.
Input Over voltage:
Automatic shutdown.
Input Over voltage
Transients:
Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.
Output Over current:
Adjustable level constant current mode with programmable set point.
Output Short Circuit:
Peak and RMS current limit.
Over temperature:
Automatic shutdown.
2.2 Mechanical
Parameter
Specification
Dimensions:
(for each MX chassis)
Height: 50.0”
1270
mm
Width: 28.75”
731
mm
Depth:
34.5”
876 mm
Unit Weight:
(for each MX chassis)
Net:
1150 lbs / 522 Kg
approximately
Shipping:
1231 lbs / 560 Kg
approximately
Material:
Steel chassis with aluminum panels and covers.
Finish:
Light textured painted external surfaces.
Panels semi-gloss polyurethane color no. 26440 (medium gray)
Cooling:
Fan cooled with air intake on the front and exhaust to the rear.
Fans:
6 x 225CFM.
Air displacement
22 Cu Ft/sec. Max.
Internal Construction:
Modular sub assemblies.
Rear Panel
Connections:
(See section 3 for description of connections)
•
Cable entry and strain relieve for AC input wiring
•
Cable entry and strain relieve for output wiring
•
External sense terminal block (Remote voltage sense)
•
System interface (2x)
•
Clock and Lock BNC's (requires -LKM or -LKS options)
•
RS232, USB, GPIB, LAN (option)
•
Trigger In BNC
•
Trigger Out BNC
•
Function Strobe BNC
•
Output Status
22 MX
Series
Содержание MX30-1
Страница 4: ...User Manual Rev AJ California Instruments 4 MX Series ...
Страница 33: ...User Manual Rev AJ California Instruments MX Series 33 ilter option schematic Figure 2 12 MX output f ...
Страница 34: ...User Manual Rev AJ California Instruments Figure 2 13 MX45 Output Noise 10 KHz 1 MHz 34 MX Series ...
Страница 50: ...User Manual Rev AJ California Instruments Figure 3 11 MX135 or MX135 MB Output Wiring Rear view 50 MX Series ...
Страница 147: ...User Manual Rev AJ California Instruments Output Status Available on top assembly 7003 427 only MX Series 147 ...
Страница 148: ...User Manual Rev AJ 148 California Instruments MX Series Figure 5 2 MX Series Detailed Block Diagram ...
Страница 149: ...User Manual Rev AJ MX Series California Instruments 149 Figure 5 3 Power Module Detailed Block Diagram ...
Страница 195: ...User Manual Rev AJ California Instruments Figure 9 4 Voltage Modulation MX Series 195 ...