User Manual - Rev AJ
California Instruments
9.5 Op o
IE
ti n –413:
C 61000-4-13 Interharmonics Test
9.5.1 General
The IEC413 option is capable of performing IEC 61000-4 se
harmonics low frequency immunity tests. The tests are based on IEC 61000-4-13:2002-03, First
ction 13 Harmonics and inter
Edition. It is assumed that the user has a copy of the test standard available. This manual
section only covers operation of the –413 option from the front-panel of the MX Series power
source.
Note 1:
The initial release of the –413 option for the MX Series power sources was based on a
draft version (CDV) of the IEC 61000-4-13 standard. Minor changes were made between the
CDV draft and the fina
on 0.31 or higher conform to
contacting
supp
l released version. Units with firmware revisi
the official released IEC standard. Units with older firmware conform to the draft version. A
firmware upgrade can be ordered through California Instruments’ service department by
and requesting part number CIC637. Provide the model an
al
m
f the unit (master unit in multi-box systems) to ensure the correct firmware is
d
seri nu ber o
i
few ec ds. It
Wh e r levant,
tain specific test modes is
Note 2:
or M 45 3 Serie
rbitrary waveform capability.
9.5.2 Initial
provided. The f rmware revision is displayed on the LCD screen immediately after power up for a
s on
can also be queried over the bus using the “*IDN?” command.
er
e
the requirement for the correct firmware revision to ob
indicated in this manual.
The –413 option is only available on MX45-3Pi Series AC power sources, not MX45-1
X -
s as it requires a
Setup
The user must set the operating voltage and close the output relay prior to the start of test. The
1.
2.
9.5.3 T
following set of parameters must be set before the start of test.
Frequency to 50 or 60 Hz.
Voltage mode to AC.
3. Waveform to sine wave.
ests Performed
The IEC1000-4-13 test consists of several types of tests. These tests can be run individually or
in sequence (ALL). The following tests are available:
1. Harmonic combination test flat curve and over swing.
2. Sweep in frequency and resonance frequency detection.
Individual harmonics and inter harmonics.
Mei
3.
4.
ster curve test (Firmware revision 0.31 or higher required)
MX Series
213
Содержание MX30-1
Страница 4: ...User Manual Rev AJ California Instruments 4 MX Series ...
Страница 33: ...User Manual Rev AJ California Instruments MX Series 33 ilter option schematic Figure 2 12 MX output f ...
Страница 34: ...User Manual Rev AJ California Instruments Figure 2 13 MX45 Output Noise 10 KHz 1 MHz 34 MX Series ...
Страница 50: ...User Manual Rev AJ California Instruments Figure 3 11 MX135 or MX135 MB Output Wiring Rear view 50 MX Series ...
Страница 147: ...User Manual Rev AJ California Instruments Output Status Available on top assembly 7003 427 only MX Series 147 ...
Страница 148: ...User Manual Rev AJ 148 California Instruments MX Series Figure 5 2 MX Series Detailed Block Diagram ...
Страница 149: ...User Manual Rev AJ MX Series California Instruments 149 Figure 5 3 Power Module Detailed Block Diagram ...
Страница 195: ...User Manual Rev AJ California Instruments Figure 9 4 Voltage Modulation MX Series 195 ...