The lower display line shows the actual value. You enter the new value, using the number keys.
The digits fill the entry field from right to left, like with a pocket calculator. The key
may be
used to delete the last digit.
To accept the edited value, press
. This checks the entered value against its limits and
executes the parameter change. Pressing
twice (the first key press clears the display)
leaves the editing mode without changing anything.
In the SELECT TRACKING MODE menu, you can change the tracking mode as shown below:
OFF
STEP
ADAPTIVE
PROGRAM
For detailed information about tracking please refer to
chapter 8.3 Step Tracking
,
chapter 8.4
Adaptive Tracking
and
chapter 8.5 Program Tracking
.
The sat-nms ACU may be controlled remotely by a monitoring and control application either
through the TCP/IP interface or through a serial RS232 interface (RS232 not yet implemented in
ACU19 and ACU-RMU). Both communication methods use the same commands and parameters.
However, there are different frames around each message depending communication method
used.
Controlling the device from the web interface, the TCP/IP remote control interface or via the serial
interface is completely equal, commands may sent to any interface at any time, the ACU will use
the parameter it receives last.
The ACU knows a number of parameters, each identified by a parameter name. To set a certain
parameter to a new value, a message:
name=value
has to be sent to the ACU. The ACU interprets this command, checks the range of value , sets the
internal parameter and then answers:
name=value
The value in the reply is the value actually recognized by the ACU. For instance, if the requested
value was out of range, the replied (and internally used) value is limited to the applicable
minimum or maximum.