Function 

The solar  water heater  is designed  with an  internal coil  and  backup 
electric  heating  element.  A  heating  medium  is  passed  through  the 
solar  panels  and  internal  coil  as  long  as  there  is  an  adequate 
temperature difference between the heating medium and stored water 
in  the  tank.  The  internal  coil  is  located  as  close  to  the  bottom  as 
possible  to  facilitate  the  transfer  of  heat  even  at  lower  solar  panel 
temperatures. 
During  periods  of  water  flow  through  the  water  heater,  hot  water  is 
drawn  from  the  top  of  the  heater  and  cold  water  is  delivered  to  the 
bottom  of  the  tank  (by  a  dip  tube  or  bottom  inlet).  If  the  hot  water 
demand should exceed the solar heat input or there is an insufficient 
temperature  difference  between  the  heating  medium  and  stored 
water,  the  heating  element  thermostat  will  activate  the  electrical 
heating element for backup heat or boiler backup top coil. 
Solar heat output from the internal coil will vary depending on outside 
conditions and the temperature of the stored water. 

Models: 

NAS20053  Tank 50 gallon with lower coil and back up electric element 
NAS20083  Tank 80 gallon with lower coil and back up electric element 
NAS20123  Tank 119 gallon with lower coil and back up electric element 
NAS20082  Tank 80 gallon with lower coil and top coil for boiler back up 
NAS20122  Tank 119 gallon with lower coil and top coil for boiler back up

Power requirements: 

 240 VAC 

Power consumption: 

  4.5 KW 

Agency approval 

 UL listed

REV1 8/08

Technical characteristics 

Tank materials:  

      porcelain coated steel

Tank insulation:      

      2” non-CFC foam

Tank external cover: 

 powder-coated steel (20-24 ga.) 

Anode rods: 

 2 each magnesium

 

Internal heat exchanger coil (lower): 

1-1/2” x 30’ (50 gallon)

1-1/2” x 36’ (80, 119 gallon)

Internal heat exchanger coil (top):  

1-1/2” x 24’

Maximum working pressure:  

150 psi

Testing pressure: 

     300 psi

Recommended maximum hot water temperature 

      120°F

 

 

Temperature and pressure relief valve

210°F/150 psi max

23500.0

3

 

Insulation thermal  conductivity:

R14

Содержание NAS200 Series

Страница 1: ...ctrical heating element for backup heat or boiler backup top coil Solar heat output from the internal coil will vary depending on outside conditions and the temperature of the stored water Models NAS2...

Страница 2: ...ons thoroughly before installing or placing the heater into service This unit must be installed by licensed or authorized installers or technical personnel that service water heating equipment The hea...

Страница 3: ...nstructions 4 Use this water heater only for its intended use as described in this manual 5 Do not use an extension cord set with this water heater If no receptacle is available adjacent to the water...

Страница 4: ...Table of Contents 1 Specifications 5 2 General Information 6 3 Pre Installation 9 4 Installation 10 5 Operation 16 6 Maintenance 17 7 Troubleshooting 18 8 Parts List 19 Page 4...

Страница 5: ...tection valve be installed and used according to the manufacturer s directions to prevent scalding Model A B C D E F G H I J K NAS20053 22 48 1 4 39 3 4 39 3 4 31 1 2 16 3 4 6 1 2 n a n a n a n a NAS2...

Страница 6: ...58 0 8 NAS20122 108 2 76 1 84 14 14 9 42 0 60 0 40 258 158 1 2 NOTES Based on 5 GPM flow rate Based on solar input of 140 F 2 GPM Depending on model backup heat recovery is calculated with either a 45...

Страница 7: ...heater and cannot be adjusted The thermostat is factory set at 120 F See Table 6 for thermostat letter and temperature relationships If hotter water is required a thermostatic mixing device or scald...

Страница 8: ...valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements for Relief Valves and Autom...

Страница 9: ...witch do not use any telephone in your building Immediately call your gas supplier from a telephone in another building Follow your gas supplier s instructions If you cannot reach your gas supplier ca...

Страница 10: ...ion and shut off valve at both potable water connections All piping should be diameter new copper or larger A thermostatic mixing valve or scald protection valve should be installed at the potable wat...

Страница 11: ...ATION cont A piping diagram for a typical solar domestic water heating system based on an indirect water heater with electric heating backup is shown in Figure 3 Figure 3 Single tank system with elect...

Страница 12: ...gure 4 Two tank system with existing heater A typical two tank system is shown in Figure 4 The two tank system is mainly used where a conventional water heater is already installed SECTION IV INSTALLA...

Страница 13: ...of a domestic solar heating system based on an indirect water heater with two coils The domestic water can be heated by the solar system as well as the boiler Figure 5 Single tank system with boiler b...

Страница 14: ...oiler fired water heater SECTION IV INSTALLATION cont Figure 6 shows a two tank system based on an indirect water heater and a solar water heater with electric back up The stored water in the indirect...

Страница 15: ...with copper conductors over current protection and means for disconnection must be provided by qualified service personnel The total wattage load and voltage requirements for the water heater are spe...

Страница 16: ...led VERY HOT See Table 6 for a listing of indicator setting and temperature relationships CAUTION Hot water in excess of 120 F can cause scalding The temperature at which injury occurs varies with the...

Страница 17: ...and at least yearly once a time interval for inspection has been developed It is recommended to check the rod s six months after the heater is installed If the anode rod had reduced in size by two th...

Страница 18: ...ection VI for tank flushing procedure Circulator does not operate Check solar controller Replace as necessary Faulty tank thermostat Replace thermostat Insufficient hot water Rust staining bad taste a...

Страница 19: ...Bracket 9 Cold Inlet with Diptube 19 Thermostat 10 Anode Rod 20 Heating Element Gasket Table 8 NAS20083 NAS20123 Parts 1 Immersion Well 10 T P Relief Valve 2 Leak Detector 11 Drain Valve 3 J Box Cover...

Страница 20: ...Heating Element Gasket Table 8 NAS20083 NAS20123 Parts 1 Immersion Well 10 T P Relief Valve 2 Leak Detector 11 Drain Valve 3 J Box Cover 12 Access Cover 4 J Box Cover w conduit hole 13 Foam Dam Cover...

Страница 21: ...e 8 NAS20083 NAS20123 Parts 1 Immersion Well 10 T P Relief Valve 2 Leak Detector 11 Drain Valve 3 J Box Cover 12 Access Cover 4 J Box Cover w conduit hole 13 Foam Dam Cover 5 Anode Rod 14 Thermostat C...

Страница 22: ...NOTES Page 22...

Страница 23: ...Page 23 NOTES...

Страница 24: ...Caleffi North America Inc 3883 W Milwaukee Rd Milwaukee WI 53208 Copyright 201 Tel 414 238 2360 Tel 414 238 2366 Printed in the USA 8...

Отзывы: