Installation Instructions

PROVENCE

Dimensions

NOTE: All dimensions are approximate; measure your spa before making  

critical design or pathway decisions.

NOTE:

 

WATKINS WELLNESS

 recommends that the 

PROVENCE

 be installed on a minimum 10 cm thick reinforced concrete pad or structurally sound deck able to support 

the “dead weight” found in the spa specification chart.

WARNING:

 The 

PROVENCE

 must not be shimmed in any manner. 

84.0” (213 cm)

31” 

(79 cm)

35” 

(89 cm)

78.5” (199 cm)

71.85”  

(182.5 cm)

PROVENCE

69.5” (177 cm)

37.875” (96 cm)

13” 

(33 cm)

78”  

(198 cm)

Door Opening

Drain

(Center of Spa)

Electrical Cut-Out 

(both sides)  

4" (10 cm) up from 

bottom of spa

Base Pan

Side Walls

Base Pan Side Walls

Air Vent

Do Not Block

Air Vent

Do Not Block

Air Vent

Do Not Block

DOOR SIDE

Electrical Cut-Out 

(both sides)

(Front View)

(Bottom View)

Cabinet

Содержание UTOPIA CANTABRIA

Страница 1: ...UTOPIA SERIES 2 0 1 8 O W N E R S M A N U A L 5 0 H z...

Страница 2: ...SERIAL NUMBER ___________________________ COVER SERIAL NUMBER _______________________________ In most cities and counties permits will be required for the installation of electrical circuits or the co...

Страница 3: ...EL 18 CANTABRIA ULTRAMASSEUSE CONTROL PANEL 18 JET MENU CANTABRIA 20 GENEVA 21 NIAGARA 22 TAHITIAN 23 FLORENCE 24 PROVENCE 25 SPA CARE AND MAINTENANCE FILTER MAINTENANCE 26 FILTER CARTRIDGE REMOVALAND...

Страница 4: ...rated audio video equipment through the spa control panel or wireless remote is permitted and acceptable Do not connect any auxiliary components for example cable additional speakers headphones additi...

Страница 5: ...e recommended levels for your CALDERA spa are Free Available Chlorine 3 0 5 0 ppm Total Alkalinity 40 120 ppm Water pH 7 2 7 8 Calcium Hardness 50 150 ppm Refer to Water Quality and Maintenance sectio...

Страница 6: ...can easily be diagnosed over the telephone by an Authorized Service Technician SPA SHELL Your CALDERA spa has an acrylic shell Stains and dirt generally will not adhere to your spa s surface Asoft ra...

Страница 7: ...aptaFlo jet allow you to redirect the jet stream by changing the position of the nozzle 9 The Euro Directional jets with eyeball nozzles deliver a direct more focused massage 10 The Euro Pulse jets fe...

Страница 8: ...unter clockwise to reduce the force or clockwise to increase the force Notice that turning off the flow to some jets increases the flow to the other jets To avoid damage to your spa s plumbing and com...

Страница 9: ...pH Alkalinity Up Down available Know the Hardness of your water contact your dealer to help you with this information See Water Quality and Maintenance for more information IMPORTANT WATKINS WELLNESS...

Страница 10: ...0 ppm then spa water pH to between 7 2 and 7 8 These procedures are listed in the Water Quality and Maintenance section OPERATION NOTE Adjusting the Total Alkalinity as the first step is important as...

Страница 11: ...a responsible person to handle spa chemicals Keep them out of the reach of children Accurately measure the exact quantities specified never more Do not overdose your spa Handle all containers with car...

Страница 12: ...ween 7 2 7 8 To lower the pH level use MONARCH pH Alkalinity Down sodium bisulfate To raise the pH level use pH Alkalinity Up sodium carbonate Water Conditioners Spa fill water varies from location to...

Страница 13: ...spa by adding MONARCH MPS Plus non chlorine shock shock or sodium dichlor chlorine To replace FROG cartridges follow these steps 1 Turn off power to the spa 2 Unscrew FROG cap on top edge of spa 3 Tur...

Страница 14: ...hlorine chloramines has a strong chlorine odor that can be eliminated by shocking the water IMPORTANT There are several forms of stabilized chlorine available for use in spas and swimming pools It is...

Страница 15: ...popular water additives that are optional Mineral Deposit Inhibitors As water evaporates from your spa and new water is added the amount of dissolved minerals will increase Minimize evaporation by ke...

Страница 16: ...f nitric acid a highly corrosive chemical is a byproduct of the ozone generating process Nitric acid is produced in very small quantities and is readily dissolved in the water stream with ozone Oxidiz...

Страница 17: ...ycle is on 38 0c Settings Screen Press this icon to access the first Settings screen Home Screen Features 38 0c Jets Press this icon to access the Jets Control screen 38 0c Music If installed press th...

Страница 18: ...Summer Timer On or Off TEMPERATURE LOCK Press 38 0c on Home screen to display Temperature Lock The Temperature Lock feature prevents changing the desired water temperature setting All other control p...

Страница 19: ...SPA LOCK OFF ON LIGHTS TIMER OFF ON SUMMER TIMER OFF ON to see more languages Press and hold on the new desired language until it turns green Press to start the conversion process The conversion is f...

Страница 20: ...S section and the ALL LIGHTS section MOODS Preset colors and brightness LIGHTS 1 2 3 4 MOODS ALL LIGHTS Press to turn On Underwater lights blue color LIGHTS 1 2 3 4 MOODS ALL LIGHTS Press to turn On U...

Страница 21: ...rnal lights on full intensity 5th press Underwater lights and EUPHORIA Jets lights on low intensity external lights on full intensity 6th press Underwater lights and EUPHORIA Jets lights off external...

Страница 22: ...k Jet Leg Jets Neck and Upper Back Jets Lower Back and Feet Jets Leg Jets Neck and Upper Back Jets Lower Back and Feet Jets Lower Back and Feet Jets Step 6 Lower Back and Feet Jets Leg Jets Leg Jets L...

Страница 23: ...URO PULSE jets d 4 Euro Directional jets e 1 ACQUARELLA Waterfall a b b c c d d e JET PUMP 2 JET SYSTEM 1 a 8 Euro Directional jets b 2 VERSASSAGE jets c 2 EURO PULSE jets d 1 ACQUARELLA Waterfall a a...

Страница 24: ...1 EUPHORIA jet f ACQUARELLA Waterfall JET PUMP 2 JET SYSTEM 1 Located in ULTRAMASSAGE lounge a 2 VERSASSAGE jets b 2 ORBISSAGE jets c 6 Euro Directional jets d 6 Sole Soothers jet e ACQUARELLA Waterf...

Страница 25: ...MP 1 JET SYSTEM 1 a 2 VERSASSAGE jets b 4 Euro Directional jets c 1 EUPHORIA jet JET PUMP 2 JET SYSTEM 2 Located in ECSTASEAT a 2 Directional Neck jets b 2 Euro Directional jets Located in ULTRAMASSAG...

Страница 26: ...SSAGE jets d 2 ORBISSAGE jets e ACQUARELLA Waterfall JET PUMP 1 JET SYSTEM 2 a 2 Euro Directional jets b 1 ADAPTAFLO jet Located in LUMBARSSAGEseat c 2 VERSASSAGE jets d 6 Euro Directional jets e 1 AD...

Страница 27: ...P 1 JET SYSTEM 1 Located in LUMBARSSAGEseat a 2 Euro Directional jets b 2 ORBISSAGE jets c 2 VERSASSAGE jets d 2 Euro Directional jets e 2 ADAPTASSAGE jets JET PUMP 2 JET SYSTEM 1 Located in ECSTASEAT...

Страница 28: ...SAGE lounge a 2 Directional Neck jets b 12 Euro Directional jets c 2 ORBISSAGE jets d 2 VERSASSAGE jets JET PUMP 2 JET SYSTEM 1 Located in ECSTASEAT lounge a 22 Euro Directional jets b ACQUARELLA Wate...

Страница 29: ...filter cartridge To return basket and floating weir insert and rotate clockwise to lock into position Then turn spa s power back on NOTE Replacement filter cartridges are available from your CALDERA d...

Страница 30: ...correctly can lead to freeze damage not covered by warranty It is strongly recommended that you contact your local dealer to perform this service 1 Drain your spa following the Draining Your Spa secti...

Страница 31: ...ohol or any other household cleaner other than those listed to clean the spa shell surface is NOT recommended DO NOT use any cleaning products containing abrasives or solvents since they may damage th...

Страница 32: ...ditional 16 amp breaker the heater will NOT operate while the jets in the lounge jet pump 3 are on Mount the subpanel according to local codes but not closer than 1 5 meters 5 feet away Your spa must...

Страница 33: ...maximum safety against electric shock Remember connecting the spa to an improperly wired circuit will negate many of its safety features NOTE Long wiring runs may require larger gauge wire than state...

Страница 34: ...ting Your CALDERA dealer can help you with local information such as zoning regulations and building codes They can also give you a copy of our planning guide CAUTION Do not install the spa on a heate...

Страница 35: ...nforced concrete pad at least 10 cm 4 inches thick or a deck that is able to withstand more than 515 kg m is recommended for the PROVENCE 610 kg m is recommended for TAHITIAN spa and 600 kg m is recom...

Страница 36: ...ons are approximate measure your spa before making critical design or pathway decisions 108 0 274 cm 32 5 83 cm 38 97 cm 102 0 259 cm 85 125 216 cm Cantabria 93 375 237 cm 13 33 cm 61 5 156 cm 91 231...

Страница 37: ...o support the dead weight found in the spa specification chart WARNING The GENEVA NIAGARA must not be shimmed in any manner Niagara Geneva 89 226 cm 32 5 83 cm 38 97 cm 83 5 212 cm 83 5 212 cm 75 190...

Страница 38: ...imensions are approximate measure your spa before making critical design or pathway decisions 84 0 213 cm 31 79 cm 36 91 cm 78 25 199 cm 78 25 199 cm TAHITIAN 69 5 177 cm 37 875 96 cm 13 33 cm 84 213...

Страница 39: ...e to support the dead weight found in the spa specification chart WARNING The PROVENCE must not be shimmed in any manner 84 0 213 cm 31 79 cm 35 89 cm 78 5 199 cm 71 85 182 5 cm PROVENCE 69 5 177 cm 3...

Страница 40: ...to note that the heater is protected by both the heater high limit thermostat circuit and the integrated pressure switch The causes of heater high limit tripping are discussed in the previous section...

Страница 41: ...n equal to the duration of the applicable limited warranty stated above Some states do not allow limitations on how long an implied warranty lasts Under no circumstances shall WATKINS WELLNESS or any...

Страница 42: ...Gray Logo Power indicator blinking Heater high limit thermostat tripped Disconnect power for at least thirty seconds to reset heater high limit If it will not reset check for clogged filters If tripp...

Страница 43: ...or panel away from the spa next to that button location Repeat procedure on second button Main Control Panel Safety Lock DOOR PANEL REPLACEMENT 1 Raise door panel placing top under Stainless border wi...

Страница 44: ...circuit NIAGARA 226 cm x 226 cm 97 cm 10 m 3 000 1 525 liters 450 kg 2 535 kg 600 kg m 230 volt 16 and 25 amp Single phase GFCI protected circuit TAHITIAN 213 cm x 213 cm 91 cm 10 m 3 000 1 425 liter...

Отзывы: