CAL
-SERIES
26
45° TILT (ALL LENGTHS)
NOTE: 45° Tilt is NOT RECOMMENDED. This angle of tilt causes the ambient air to form a convection
current over the tube. The net effect of this action is reduced infrared output (decreased heating
capacity) as well as decreased exhaust temperature which may increase the chance of condensation
of combustion by-products.
Figure 22. 45° TILT