CAL
-SERIES
10
VENTED
Figure 3. VENTED CLEARANCES
6.1
CLEARANCE TO COMBUSTIBLES FOR SPACE HEATING AND BROODER INSTALLATION
IN THE USA:
Residential Garage heater installations with less than an 8' (2.44 m) clearance from the bottom
of the tube to the floor require the installation of the Protective Screen Kit PIN#3900212 (see page 20 for
details) The minimum floor clearance is 6' (1.83 m) from the floor to the bottom of the reflector.
IN CANADA:
Residential Garage heater installations with less than an 7' (2.14 m) clearance from the bottom
of the tube to the floor require the installation of the Protective Screen Kit PIN#3900212 (see page 20 for
details) The minimum floor clearance is 6' (1.83 m) from the floor to the bottom of the reflector.
WARNING:
I
n all situations, clearances to combustibles must be maintained. Minimum clearance
from heater must be maintained from vehicles parked below heater. The posting of signs may be
required in storage areas referring to clearances to combustibles to the heater and/or limiting the
stacking height of stored Items near the heater specifying a maximum height. Clearances are not for use
in four (4) sided enclosures. Certain materials or items, when stored under the heater, will be subjected
to radiant heat and could be seriously damaged.
WARNING
:
The stated clearance to combustibles represents a surface temperature of 90°F (32°C)
above room temperature. Building material with low heat tolerance (such as plastics, vinyl siding, canvas,
tri-
ply, etc…) may be subject t
o degradation at lower temperatures. It is the installer's responsibility to
assure that adjacent materials are protected from degradation. When in doubt, check heat tolerance of
building material(s) with their manufacturer.
Содержание CAL Series
Страница 18: ...CAL SERIES 14 CAL 40A 50A 15 4 16 M Figure 7 CAL 40A 50A 15 4 16 M...
Страница 20: ...CAL SERIES 16 CAL 40A 50A 15 4 16 M THREE PIECE MODEL Figure 9 CAL 40A 50A 15 4 16 M THREE PIECE MODEL...
Страница 21: ...CAL SERIES 17 CAL 40A 50A 75A 20 6 1 M FOUR PIECE MODEL Figure 10 CAL 40A 50A 75A 20 6 1 M FOUR PIECE MODEL...
Страница 23: ...CAL SERIES 19 90 ELBOW PACKAGE Figure 13 90 ELBOW PACKAGE 180 U BEND PACKAGE Figure 14 180 U BEND PACKAGE...
Страница 37: ...CAL SERIES 33 90 ELBOW KIT Figure 29 90 ELBOW KIT INSTALLATION 180 U BEND KIT Figure 30 180 U Bend Kit...
Страница 63: ...CAL SERIES 59 24 0 GAS VALVES Figure 47 GAS VALVE...
Страница 83: ...CAL SERIES 79...