Cal Test Electronics CT4024 Скачать руководство пользователя страница 1

CT4024

User  Manual                              

Содержание CT4024

Страница 1: ...CT4024 User Manual...

Страница 2: ...ategory I CAT I only Do not exceed 60 seconds of contact with high voltage When making contact between this probe and any circuit with voltages 8 kV DC 5 kVrms AC or 15 kVpk pk AC wait for 5 minutes b...

Страница 3: ...liquid being spilled on the instrument z z In air temperatures exceeding the specified operating temperatures z z In atmospheric pressures outside the specified altitude limits or where the surroundin...

Страница 4: ...or the entire product Compliance Statements Disposal of Old Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This product...

Страница 5: ...Overview The Elditest CT4024 is an 8 kV High Voltage divider probe for use with both digital and analog oscilloscopes Features z z Measures up to 8 kV DC ACpk or 6 kVrms AC z z 40 MHz bandwidth z z V...

Страница 6: ...4 Connect the divider probe ground lead alligator clip to a good earth ground or reliable chassis ground 5 Before turning on the high voltage source be certain the operator is not touching any part of...

Страница 7: ...whenever the probe is connected to or transferred between oscilloscopes The procedure is the same as for a x10 passive probe z Connect the probe to the oscilloscope z Connect probe tip to square wave...

Страница 8: ...1028 caltestelectronics com 7 Figure 2 shows how over and under compensated pulse responses will look Figure 2 Over Under Compensation Figure 3 shows a perfectly compensated probe Figure 3 Good Compe...

Страница 9: ...fficient 200 ppm C Input Resistance 100 M 5 Rise Time 9 ns Accuracy DC Volts 3 below 8 kV AC Volts 3 at 1 kHz 3 dB 0 to 40 MHz General Cable Length 6 6 ft 2 m Designed for Use in Pollution Degree 2 Op...

Страница 10: ...572 1028 caltestelectronics com 9 5 Voltage Derating Curve WARNING When measuring higher frequency signals be sure to comply with the Voltage vs Frequency Derating Curve Figure 4 Voltage Derating Cur...

Страница 11: ...ginal purchase Under this warranty Cal Test Electronics is limited to repairing the defective device when returned to the factory shipping charges prepaid within the warranty period Units returned to...

Страница 12: ...representative of Cal Test Electronics is authorized to assume any other obligation in connection with the sale and purchase of this device Service If you have a need for calibration or repair service...

Страница 13: ...800 572 1028 caltestelectronics com 12 Notes...

Страница 14: ...800 572 1028 caltestelectronics com 13...

Страница 15: ...800 572 1028 caltestelectronics com 14...

Страница 16: ...800 572 1028 caltestelectronics com 15...

Отзывы: