Delivery and Set-Up
Page 8
2005 Spa Owner's Manual
7/21/2005
inches (127 mm) above the floor. The openings shall be equally sized, spaced at 180Þ (3.14 rad) and
unobstructed.
c.
Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2 mm)
diameter rod.
LP Gas Manifold Pressure
For plumbed-in LP installation, use a convertible regulator and set it for LP gas.
LP Gas Supply Pressure
Maximum line pressure for plumbed-in propane is 14” WC psi (3.5 kPa). Minimum line pressure for propane is
11” WC.
LP Gas Pressure Regulator
The unit must be used with the gas pressure regulator. The regulator will control and maintain a uniform gas
pressure in the manifold. The burner orifices have been sized for the gas pressure delivered by the regulator.
LP Gas Cylinder Specification
Any LP gas supply cylinder used with this grill must be approximately 12 inches in diameter and 18 inches
high. The maximum fuel capacity is 20 lbs. of propane, or 5 gallons. Full cylinder weight should be
approximately 38 lbs. (43.7 lbs. nominal water capacity.) Always use the cylinder dust cap on the cylinder
valve outlet during transport and when the cylinder is not connected to the grill.
Transporting the LP Gas Supply Cylinder
Transport only one cylinder at a time. Transport each cylinder in an upright and secure manner with the control
valve turned off and the dust cap in place.
Leak Testing Procedure for LP Gas
Perform a leak test at least once each year whether the gas supply cylinder has been disconnected or not. In
addition, whenever the gas cylinder is connected to the regulator or whenever any part of the gas system is
disconnected or replaced, perform a leak test.
As a safety precaution, remember to always leak test your grill outdoors in a well-ventilated area. Never smoke
or permit sources of ignition in the area while doing a leak test. Do not use a flame, such as a lighted match to
test for leaks. Use only a leak testing solution of sudsy water.
1.
Prepare a leak testing solution of sudsy water by mixing in a spray bottle one part liquid soap to one part
water.
2.
Make sure all the control knobs are in the OFF position.
3.
Turn the cylinder valve knob counter clockwise one turn to open.
4.
Apply the leak-testing solution by spraying it on joints of the gas delivery system. Blowing bubbles in the
soap solution indicates that a leak is present.
5.
Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part
recommended by the manufacturer. Do not attempt to repair the cylinder valve if it is damaged. The
cylinder must be replaced.